Microvascular flow imaging of fibroids: A prospective pilot study

Author:

Frijlingh Marissa12ORCID,Stoelinga Barbara12,de Leeuw Robert A.12,Hehenkamp Wouter J. K.12,Twisk Jos W. R.3,van den Bosch Thierry4,Juffermans Lynda J. M.12,Huirne Judith A. F.12

Affiliation:

1. Department of Obstetrics and Gynecology Amsterdam UMC, location AMC Amsterdam The Netherlands

2. Amsterdam Reproduction and Development Research Institute Amsterdam The Netherlands

3. Department of Epidemiology and Biostatistics Amsterdam UMC, location VUmc Amsterdam The Netherlands

4. Department of Obstetrics and Gynecology University Hospital KU Leuven Leuven Belgium

Abstract

AbstractIntroductionImaging fibroid vascularity may predict fibroid growth and aid to determine most appropriate therapy. Microvascular (MV) flow imaging is relatively new and is able to detect slow flow in small vessels. Data on feasibility, reproducibility, and reliability of MV‐flow imaging in fibroids is lacking. The purpose of our study was to determine the reproducibility of MV‐flow imaging and to explore this technique for clinical practice for assessing blood flow in fibroids.Material and MethodsThirty patients with one or multiple fibroids (diameter 1.5–12.0 cm) were prospectively included. Transvaginal ultrasound scanning was performed in B‐mode, 2D MV‐Flow™, 2D and 3D power Doppler mode (HERA W10, Samsung) by two experienced gynecologists at a tertiary care clinic from February to December 2021. The primary outcome was intra‐ and interobserver agreement of the vascular index (VI) and color score (CS). The following parameters: ‘2D MV‐flow VI’, ‘3DPD VI’, ‘2D MV‐flow CS’ and ‘2DPD CS’ were measured offline in the center, pseudocapsule, and entire fibroid. Secondary offline outcomes for exploring 2D MV‐flow for clinical practice, included (1) ability to discern vascular structures, (2) assessing the degree of vascularity via CS and calculating a VI, and (3) determining penetration depth of the ultrasound signal in both power Doppler and MV‐flow imaging.ResultsAll scans of the 30 included patients were of sufficient quality to analyze. Inter‐ and intra‐observer correlations of all studied parameters were good to excellent, both for 2D MV‐flow and 2D power Doppler (intercorrelation coefficient 0.992–0.996). Using 2D MV‐flow different vascular structures were visible in detail, in contrary to using 2D and 3D power Doppler. In significantly more fibroids central flow could be visualized using 2D MV‐flow (63%) than with 2D power Doppler (13%, p = 0.001). Finally, penetration of the ultrasound signal was deeper using 2D MV‐flow (3.92 cm) than with 2D power Doppler (2.95 cm, p = 0.001).ConclusionsUsing 2D MV‐flow imaging for determining vascularity is highly reproducible. It has potential added value for clinical practice as it depicts detailed vascular structures and the degree of vascularity, especially in the center of the fibroid.

Publisher

Wiley

Reference35 articles.

1. Ultrasonography of uterine leiomyomas;Woźniak A;Prz Menopauzalny,2017

2. A pictorial review of ultrasonography of the FIGO classification for uterine leiomyomas;Bajaj S;Abdom Radiol,2022

3. Self‐reported heavy bleeding associated with uterine leiomyomata;Wegienka G;Obstet Gynecol,2003

4. The natural history of fibroids;Mavrelos D;Ultrasound Obstet Gynecol,2010

5. Fibroid vascularisation assessed with three‐dimensional power Doppler ultrasound is a predictor for uterine fibroid growth: a prospective cohort study;Nieuwenhuis LL;BJOG,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3