Autoclaving‐induced dimensional changes of three‐dimensional printed surgical guides: An in vitro study

Author:

Hüfner Mira1ORCID,David Samuel1,Brunello Giulia23ORCID,Kerberger Robert1,Rauch Nicole2,Busch Caroline Viola2,Drescher Dieter1,Bourauel Christoph4,Becker Kathrin1ORCID

Affiliation:

1. Department of Orthodontics University Hospital of Düsseldorf Düsseldorf Germany

2. Department of Oral Surgery University Hospital of Düsseldorf Düsseldorf Germany

3. Department of Neurosciences University of Padua Padua Italy

4. Oral Technology University Hospital Bonn Bonn Germany

Abstract

AbstractObjectivesSurgical guides are frequently used for dental implant placement. The aim of this study was to evaluate the impact of the 3D printing process itself and subsequent steam autoclaving on the dimensional stability of five different resin/printer combinations (RPCs).Materials and MethodsFifty identical surgical guides (10 per group) were produced consisting of five RPCs. Half of the guides (5 per group) were steam autoclaved with cycle 1 (121°C, 1 bar, 20.5 min) and the other half with cycle 2 (134°C, 2 bar, 5.5 min). All guides were scanned with a structured‐light (SL) 3D scanner before (T0) and after (T1) autoclaving. Linear measurements along the x‐, y‐, and z‐axes were performed at landmarks on the original STL file and on SL scans at T0 and T1, respectively. Wilcoxon signed‐rank test, Kruskal–Wallis test, and linear mixed‐effects models were performed, depending on the analysis.ResultsThree‐dimensional printing was associated with significant dimensional alterations for all RPCs. Steam autoclaving using cycle 1 was associated with significant shrinkage in x‐ (1 RPC), y‐ (2 RPCs), and z‐direction (2 RPCs), while cycle 2 was also associated with shrinkage in x‐ (2 RPCs), y‐ (1 RPC), and z‐direction (1 RPC). One resin did not present any dimensional changes independently of the cycle.ConclusionsThe majority of the guides presented minor but significant shrinkage due to 3D printing itself and both steam autoclaving cycles, the extent varied between different RPCs. Whether these changes compromise implant placement accuracy remains to be investigated.

Publisher

Wiley

Subject

Oral Surgery

Reference36 articles.

1. Influence of Metal Guide Sleeves on the Accuracy and Precision of Dental Implant Placement Using Guided Implant Surgery: An In Vitro Study

2. Effect of the use of a surgical guide on heat generation during implant placement: A comparative in vitro study

3. Fitting Linear Mixed-Effects Models Usinglme4

4. Effects of Postcuring Temperature on the Mechanical Properties and Biocompatibility of Three-Dimensional Printed Dental Resin Material

5. Hygiene requirements for the reprocessing of medical devices. Recommendation of the Commission for Hospital Hygiene and Infection Prevention (KRINKO) at the Robert Koch institute (RKI) and the Federal Institute for Drugs and Medical Devices (BfArM);Commission for Hospital Hygiene and Infection Prevention (KRINKO);Bundesgesundheitsblatt, Gesundheitsforschung, Gesundheitsschutz,2012

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3