Enhanced Efficiency of a Novel Porous Tip Irrigated RF Ablation Catheter for Pulmonary Vein Isolation
Author:
Affiliation:
1. Arrhythmia Department; Universitäts-Herzzentrum Freiburg-Bad Krozingen, Medizinische Klinik für Kardiologie und Angiologie II; Bad Krozingen Germany
2. Cardiology Service; Department of Medicine; University Hospital of Geneva; Geneva Switzerland
Publisher
Wiley
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Link
http://onlinelibrary.wiley.com/wol1/doi/10.1111/jce.12221/fullpdf
Reference11 articles.
1. 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society;Calkins;Heart Rhythm,2012
2. Incidence of asymptomatic intracranial embolic events after pulmonary vein isolation: Comparison of different atrial fibrillation ablation technologies in a multicenter study;Herrera Siklody;J Am Coll Cardiol,2011
3. Congestive heart failure after atrial fibrillation ablation;Singh;Europace,2009
4. Small or large isolation areas around the pulmonary veins for the treatment of atrial fibrillation? Results from a prospective randomized study;Arentz;Circulation,2007
5. Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: An in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation;Petersen;Pacing Clin Electrophysiol,2000
Cited by 31 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Impact of high-power short-duration atrial fibrillation ablation technique on the incidence of silent cerebral embolism: a prospective randomized controlled study;BMC Medicine;2023-11-23
2. Porous tip radiofrequency ablation catheter reduced heart failure‐related complications and healthcare resource utilization in paroxysmal atrial fibrillation patients;Journal of Arrhythmia;2023-03-16
3. Prevalence, Predictors and Mechanisms of Steam Pops in Ablation Index-Guided High-Power Pulmonary Vein Isolation;Journal of Cardiovascular Development and Disease;2022-12-07
4. Comparison of the lesion formation and safety in ex vivo porcine heart study: Using ThermoCool SmartTouch and ThermoCool SmartTouch‐SF catheters;Journal of Cardiovascular Electrophysiology;2021-05-05
5. Long-term safety and effectiveness of paroxysmal atrial fibrillation ablation using a porous tip contact force-sensing catheter from the SMART SF trial;Journal of Interventional Cardiac Electrophysiology;2020-05-27
1.学者识别学者识别
2.学术分析学术分析
3.人才评估人才评估
"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370
www.globalauthorid.com
TOP
Copyright © 2019-2024 北京同舟云网络信息技术有限公司 京公网安备11010802033243号 京ICP备18003416号-3