Diagnostic accuracy of a simple qualitative ultrasound assessment for the diagnosis of empty stomach in the adult: A supplementary analysis of a prospective observer‐blind randomized crossover study

Author:

Bouvet Lionel12ORCID,Desgranges François‐Pierrick23ORCID,Barnoud Sophie1,Cordoval Julien1,Chassard Dominique12

Affiliation:

1. Department of Anesthesia and Intensive Care, Hospices Civils de Lyon, Femme Mère Enfant Hospital Bron France

2. Research Unit APCSe VetAgro Sup UP 2021.A101–University of Lyon Université Claude Bernard Lyon 1 Villeurbanne France

3. Department of Anesthesia and Intensive Care L'Hôpital Nord‐Ouest Villefranche‐sur‐Saône France

Abstract

AbstractBackgroundIt has been reported that qualitative ultrasound assessment performed in the semi‐upright position had high sensitivity to detect gastric fluid volume >1.5 mL.kg−1. Nevertheless, the diagnostic accuracy of qualitative assessment for the diagnosis of empty stomach (fluid volume <0.8 mL.kg−1) has not been assessed. We aimed to assess the diagnostic accuracy of simple qualitative ultrasound assessment with and without head‐of‐bed elevation to 45° for the diagnosis of an empty stomach. We also aimed to determine the diagnostic accuracy of a composite ultrasound scale and clinical algorithm.MethodsWe performed a supplementary analysis of a prospective observer‐blind randomized crossover trial in which adult fasting volunteers attended two distinct sessions, with the head‐of‐bed angled either at 0° or 45°, in a randomized order. Three tests were performed within each session, each corresponding to a different (either 0, 50, 100, 150 or 200 mL) and randomized volume of water; the same volumes were ingested in both sessions, in a randomized order. Ultrasounds were performed 3 min after water ingestion, blindly to the volume ingested.ResultsWe included 20 volunteers in whom 120 measurements were analyzed. The sensitivity and specificity of the qualitative assessment in the semirecumbent position were 93% (95% CI: 68–100) and 89% (95% CI: 76–96), respectively. The composite scale and clinical algorithm did not have better diagnostic accuracy than the qualitative assessment performed with head‐of‐bed elevation. Without head‐of‐bed elevation, the clinical algorithm had significantly higher specificity (98% [95% CI: 88–100]) than qualitative assessment (67% [95% CI: 51–80]; p < 0.05).ConclusionThese results suggest that qualitative assessment in the semirecumbent position had high diagnostic accuracy for the diagnosis of fluid volume <0.8 mL.kg−1; this method can be used in clinical practice for reliable diagnosis of empty stomach.

Publisher

Wiley

Subject

Anesthesiology and Pain Medicine,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3