Six‐year cumulative treatment effect and treatment efficacy of a dual focus myopia control contact lens

Author:

Chamberlain Paul1ORCID,Hammond David Scott1ORCID,Arumugam Baskar1,Bradley Arthur1

Affiliation:

1. Cooper Vision Inc. San Ramon California USA

Abstract

AbstractPurposeAccumulated axial growth observed during a 6‐year clinical trial of a dual focus myopia control contact lens was used to explore different approaches to assess treatment efficacy.MethodsAxial length measurements from 170 eyes in a 6‐year clinical trial of a dual focus myopia control lens (MiSight 1 day, CooperVision) were analysed. Treatment groups comprised one having undergone 6 years of treatment and the other (the initial control group) having 3 years of treatment after 3 years of wearing a single vision control lens. Efficacy was assessed by comparing accumulated ocular growth during treatment to that expected of untreated myopic and emmetropic eyes. The impact of treatment on delaying axial growth was quantified by comparing the increased time required to reach criterion growths for treated eyes and survivor analysis approaches.ResultsWhen compared to the predicted accumulated growth of untreated eyes, 6 years of treatment reduced growth by 0.52 mm, while 3 years of treatment initiated 3 years later reduced growth by 0.19 mm. Accumulated differences between the growth of treated and untreated myopic eyes ranged between 67% and 52% of the untreated myopic growth, and between 112% and 86% of the predicted difference in growth between untreated myopic and age‐matched emmetropic eyes. Treated eyes took almost 4 years longer to reach their final accumulated growth than untreated eyes. Treatment increased the time to reach criterion growths by 2.3–2.7 times.ConclusionEstimated growth of age‐matched emmetropic and untreated myopic eyes provided evidence of an accumulated slowing in axial elongation of 0.52 mm over 6 years, and the treated growth remained close to that expected of emmetropic eyes. Six years of dual focus myopia control delayed the time to reach the final growth level by almost 4 years.

Funder

CooperVision

Publisher

Wiley

Subject

Sensory Systems,Optometry,Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3