End‐of‐day assessment of asymptomatic versus highly symptomatic soft contact lens wearers

Author:

Maldonado‐Codina Carole1ORCID,Navascues‐Cornago Maria1ORCID,Smith Sarah L.1ORCID,Read Michael L.1ORCID,Lakkis Carol23ORCID,Morgan Philip B.1ORCID

Affiliation:

1. Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health The University of Manchester Manchester UK

2. Johnson & Johnson Vision Care, Inc. Jacksonville Florida USA

3. iBiomedical Consulting Pty Ltd Melbourne Victoria Australia

Abstract

AbstractPurposeTo investigate differences in key clinical parameters between asymptomatic and highly symptomatic soft contact lens (CL) wearers after 14 h of wear.MethodsIn this pilot investigation, Phase 1 identified asymptomatic (CLDEQ‐8 score ≤ 7) and highly symptomatic (CLDEQ‐8 score ≥ 20) subjects after fitting with nelfilcon A CLs. Phase 2 investigated the following over a single nelfilcon A CL‐wearing day (14 ± 2 h): blinking characteristics, tear meniscus height (TMH), non‐invasive tear break‐up time (NIBUT), tear film osmolarity and eyelid margin staining. Parameters for the two groups were compared using linear mixed models and post‐hoc testing. The relationship between comfort scores and the clinical parameters was also investigated.ResultsOverall, 161 and 42 subjects were enrolled into Phase 1 and 2, respectively. Twenty‐five asymptomatic and 17 symptomatic subjects completed Phase 2. Lower eyelid TMH was decreased after 14 h in symptomatic compared with asymptomatic subjects (least square mean [LSM] difference −0.04 mm, 95% CI: −0.07, −0.01). Osmolarity was lower in symptomatic than in asymptomatic subjects at fitting (LSM difference −9.89, 95% CI: −18.91, −0.86). Upper eyelid margin staining was greater after 14 h in symptomatic than in asymptomatic subjects (LSM difference 0.53, 95% CI: 0.01, 1.05) and greater after 14 h than baseline in the symptomatic group (LSM difference 0.61, 95% CI: 0.16, 1.07). There was a significant relationship between comfort and upper eyelid margin staining (r = −0.40, 95% CI: −0.63, −0.11) and blink rate (r = −0.31, 95% CI: −0.57, −0.003).ConclusionThe potential parameters most effective in differentiating asymptomatic from symptomatic wearers were upper eyelid margin staining and lower TMH. The parameter with the strongest relationship to comfort was upper eyelid margin staining, where higher comfort scores were associated with lower levels of staining.

Funder

Johnson and Johnson Vision Care

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Reimagining approaches to solving common contact lens conundrums;Ophthalmic and Physiological Optics;2024-04-26

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3