Differences in radiopacity among CT contrast agents and concentrations: A quantitative study

Author:

Mehta Amit1ORCID,Roa Jorge A.2,Cannavale Kelly2,Sur Samir2,Singh I. Paul1

Affiliation:

1. Department of Neurology MedStar Georgetown University Hospital Washington District of Columbia USA

2. Department of Neuroendovascular Surgery MedStar Franklin Square Hospital Baltimore Maryland USA

Abstract

AbstractBackground and purposeSeveral studies in the literature have attempted to subjectively assess the degree of visualization of different neurovascular structures using different contrast agents and concentrations. Given the recent contrast shortages, we aim to objectively compare the radiopacity achieved with four angiographic contrast agents used in clinical practice.MethodsIsovue 370, Visipaque 320, Omnipaque 300, and Isovue 300 were each drawn up at 25%, 50%, 75%, and 100% concentrations and compared against normal saline and air syringes. CT scans were obtained, and regions of interest were analyzed for radiopacity using Hounsfield unit (HU) measurements. An aneurysm model with different contrast concentrations was also scanned and dimensions compared. Two‐tailed t‐tests and Cohen's d coefficients were applied to assess for differences in mean HU measurements.ResultsIsovue 370 and Isovue 300 had the highest and lowest mean HU, respectively (p < .001). Visipaque 320 at 25% concentration had the lowest mean HU at −.76. Statistically similar agents (p < .05) were Visipaque 320 and Omnipaque 300 at a 100% concentration (p = .30), and Omnipaque 300 and Isovue 300 at a 25% concentration (p = .73). Aneurysm dimensions among Isovue 370, Visipaque 320, and Omnipaque 300 were all similar, whereas with Isovue 300, the dimensions were significantly smaller (p < .05).ConclusionIsovue 370 provides the highest HU radiopacity and the most accurate aneurysm measurements. Angiographic measurements obtained with Isovue 300 may underestimate the actual aneurysmal dimensions. Visipaque 320 and Omnipaque 300 at 100% concentration have similar mean HUs and are beneficial for patients with chronic kidney or cardiac disease.

Publisher

Wiley

Subject

Neurology (clinical),Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3