Accuracy of template‐based guided dental implant placement—An in vitro comparison of different manufacturing methods

Author:

Sium‐Abel Aura1ORCID,Keilig Ludger12ORCID,Dörsam Istabrak12,Bourauel Christoph1

Affiliation:

1. Oral Technology Rheinische Friedrich‐Wilhelms University, University Hospital Bonn Bonn Germany

2. Department of Prosthetic Dentistry, Preclinical Education and Materials Science Rheinische Friedrich‐Wilhelms University, University Hospital Bonn Bonn Germany

Abstract

AbstractObjectivesThis study investigates effects of surgical guide manufacturing process on 3D transfer accuracy of planned dental implant position, using three production methods: additive 3D‐printed (3DF), subtractive milled (MF), and analog laboratory fabricated templates (LF).Material and MethodsImplant position for a single‐tooth gap (#26) planned digitally. 3DF and MF templates were designed digitally, while LF templates were analogously created. For each manufacturing type, 10 surgical guides were fabricated. Each guide was used for template‐guided implant placement in model replicas. For evaluation of implant placement, cone beam computed tomography scans of all implanted models were superimposed, and implant positions were determined. Deviations at implant shoulder/apex were measured, and median and inter‐quartile range (IQR) were determined for mesio‐distal, oro‐facial, coronal apico, 3D spaces, and angles.ResultsAt implant shoulder, vertical components dominated position deviations (up to 1.04 mm, IQR 0.28 mm for 3DF). Horizontal deviations were much lower (mesio‐distally up to 0.38 mm, IQR 0.36 mm (LF)). Implant apex shows similar vertical deviations, while horizontal deviations clearly increased compared to shoulder, especially in mesio‐distal direction. Median angular deviations were between 2.1° (IQR 2.0 mm, max. 4.2°) for 3DF and 3.3° (IQR 1.9 mm, max. 5.3°) for MF. No statistical differences were found between manufacturing types (Kruskal–Wallis test, p = .05).ConclusionsThe study showed the method of implant guide fabrication did not affect the accuracy of implant placement within the limits of an in vitro environment. All methods resulted in implant placement which did not exceed the accepted safety deviation envelope (1.5–2.0 mm).

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司