Application of an infrared thermography-based model to detect pressure injuries: a prospective cohort study

Author:

Jiang Xiaoqiong1,Wang Yu2,Wang Yuxin1,Zhou Min1,Huang Pan1,Yang Yufan3,Peng Fang4,Wang Haishuang5,Li Xiaomei6,Zhang Liping7,Cai Fuman1ORCID

Affiliation:

1. College of Nursing Wenzhou Medical University Wenzhou China

2. Medical Engineering Office The First Affiliated Hospital of Wenzhou Medical University Wenzhou China

3. The Second Clinical College Wenzhou Medical University Wenzhou China

4. School of Public Health and Management Wenzhou Medical University Wenzhou China

5. Cardiovascular Medicine Deparment The First Affiliated Hospital of Wenzhou Medical University Wenzhou China

6. School of Nursing Xi'an Jiaotong University Health Science Centre Xi'an China

7. The Second Affiliated Hospital of Wenzhou Medical University Wenzhou China

Abstract

Abstract Background It is challenging to detect pressure injuries at an early stage of their development. Objectives To assess the ability of an infrared thermography (IRT)-based model, constructed using a convolution neural network, to reliably detect pressure injuries. Methods A prospective cohort study compared validity in patients with pressure injury (n = 58) and without pressure injury (n = 205) using different methods. Each patient was followed up for 10 days. Results The optimal cut-off values of the IRT-based model were 0·53 for identifying tissue damage 1 day before visual detection of pressure injury and 0·88 for pressure injury detection on the day visual detection is possible. Kaplan–Meier curves and Cox proportional hazard regression model analysis showed that the risk of pressure injury increased 13-fold 1 day before visual detection with a cut-off value higher than 0·53 [hazard ratio (HR) 13·04, 95% confidence interval (CI) 6·32–26·91; P < 0·001]. The ability of the IRT-based model to detect pressure injuries [area under the receiver operating characteristic curve (AUC)lag 0 days, 0·98, 95% CI 0·95–1·00] was better than that of other methods. Conclusions The IRT-based model is a useful and reliable method for clinical dermatologists and nurses to detect pressure injuries. It can objectively and accurately detect pressure injuries 1 day before visual detection and is therefore able to guide prevention earlier than would otherwise be possible. What is already known about this topic?  Detection of pressure injuries at an early stage is challenging.Infrared thermography can be used for the physiological and anatomical evaluation of subcutaneous tissue abnormalities.A convolutional neural network is increasingly used in medical imaging analysis. What does this study add?  The optimal cut-off values of the IRT-based model were 0·53 for identifying tissue damage 1 day before visual detection of pressure injury and 0·88 for pressure injury detection on the day visual detection is possible.Infrared thermography-based models can be used by clinical dermatologists and nurses to detect pressure injuries at an early stage objectively and accurately.

Funder

Basic Public Welfare Research Project of Zhejiang Province

Publisher

Oxford University Press (OUP)

Subject

Dermatology

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3