Diagnostic performance of wide‐field optical coherence tomography angiography in detecting open‐angle glaucoma in high myopia

Author:

Zhang Yinhang1,Wang Deming1,Lin Fengbin1ORCID,Song Yunhe1,Chen Yu1,Peng Yuying1,Chen Meiling1,Liu Yuhong1,Jiang Jiaxuan1,Yang Zefeng1,Li Fei1,Zhang Xiulan1ORCID

Affiliation:

1. State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat‐sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases Guangzhou China

Abstract

AbstractPurposeTo compare the diagnostic performance of the capillary density (CD) of the central 1–6 mm and peripheral 6–12 mm annular regions in detecting open‐angle glaucoma in high myopia (HM) using 15 × 12 mm wide‐field swept‐source optical coherence tomography angiography (WF SS‐OCTA).MethodsThe study enrolled 206 and 103 eyes with HM and highly myopic open‐angle glaucoma (HM‐OAG), respectively. WF SS‐OCTA images centred on the fovea were obtained to analyse the changes in the CD in the 1–3 mm, 3–6 mm, 6–9 mm, and 9–12 mm annular regions. CD of the superficial capillary plexus (SCP) was measured with the built‐in software. The area under the receiver operating characteristic curve (AUROC) of each region was compared.ResultsThe diagnostic performance of the SCP CD in the central 1–6 mm annular region (AUROC = 0.849) was better than that in the peripheral 6–12 mm annular region (AUROC = 0.756, p = 0.001). The annular AUROCs of SCP CD peaked in the 3–6 mm annular region (AUROC = 0.858) and gradually decreased with increasing diameter and were lower than the corresponding AUROCs of the ganglion cell–inner plexiform layer thickness (p < 0.05 for all comparisons). SCP CD of the inferior quadrant in the 3–6 mm annular region had the best diagnostic performance (AUROC = 0.859).ConclusionThe SCP CD in the central 1–6 mm annular region exhibited better diagnostic performance for the detection of HM‐OAG in HM. The assessment of more peripheral regions has no added value in detecting glaucoma in HM.

Funder

National Natural Science Foundation of China

National Basic Research Program of China

Natural Science Foundation of Guangdong Province

Publisher

Wiley

Subject

Ophthalmology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Optic neuropathy in high myopia: Glaucoma or high myopia or both?;Progress in Retinal and Eye Research;2024-03

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3