Stent Design Lowers Angiographic but Not Clinical Adverse Events in Stenting of Symptomatic Intracranial Stenosis – Results of a Single Center Study with 100 Consecutive Patients

Author:

Rohde S.1,Seckinger J.1,Hähnel S.1,Ringleb P. A.2,Bendszus M.1,Hartmann M.13

Affiliation:

1. Department of Neuroradiology, University of Heidelberg Medical Center, Heidelberg, Germany

2. Department of Neurology, University of Heidelberg Medical Center, Heidelberg, Germany

3. Department of Neuroradiology, HELIOS Hospital Berlin-Buch, Berlin, Germany

Abstract

Background and aims Comparing safety and technical success of balloon-expandable stents and self-expanding stents for intracranial angioplasty and stenting in medically refractory intracranial atherosclerotic disease in a single center series. Methods Fifty-four self-expanding stents and 46 balloon-expandable stents were implanted in 100 consecutive patients (mean age 64 years, 74% male) from April 2000 to September 2009. All patients had symptomatic intracranial stenosis (anterior circulation, n = 40; posterior circulation, n = 60), presenting with recurrent transient ischemic attack or stroke under antithrombotic treatment. Mean degree of stenosis before treatment was 83 ± 13%. We assessed safety, defined as any stroke or death during the procedure and at 30 days follow-up, and technical success, defined as accurate delivery of the stent at the site of the target lesion. Results Safety – periprocedural stroke or hemorrhage occurred in 11 patients treated with balloon-expandable stent, and in 14 of the patients treated with a self-expanding stent. One patient with a balloon-expandable stent died because of acute vessel rupture during treatment. One balloon-expandable stent and one self-expanding stent patient developed a severe reperfusion hemorrhage that resulted in death. Overall, the combined stroke and death rate at 30-day follow-up was 250% (23·9% for balloon-expandable stent group and 25·9% for the self-expanding stent group, P = 0·84). Technical success – intracranial angioplasty and stenting was technically successful in 96·3% of the self-expanding stent and 89·1% of the balloon-expandable stent patients ( P = 0·31). Vascular complications were significantly less frequent in patients treated with a self-expanding stent (11·1%) than with a balloon-expandable stent (36·9%, P = 0002). Conclusion Despite a high technical success, the rate of clinical adverse events at 30 days after intracranial angioplasty and stenting is high independently of the stent design. Thus, further development of intracranial stent systems and careful patient selection are mandatory.

Publisher

SAGE Publications

Subject

Neurology

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3