Accuracy of clear aligners in the orthodontic rotational movement using different attachment configurations

Author:

Fiorillo Gianluigi1,Campobasso Alessandra2ORCID,Croce Silvia1,Hussain Umar3,Battista Giovanni2ORCID,Lo Muzio Eleonora4,Mandelli Gualtiero1,Ambrosi Alessandro1,Gastaldi Giorgio1

Affiliation:

1. Dental School San Raffaele Vita‐Salute University of Milan Milan Italy

2. Department of Clinical and Experimental Medicine University of Foggia Foggia Italy

3. Department of Orthodontics Saidu College of Dentistry Swat Pakistan

4. Department of Translational Medicine and for Romagna University of Ferrara Ferrara Italy

Abstract

AbstractObjectiveTo evaluate the accuracy of dental rotational movements using clear aligners with different attachment configurations.Materials and MethodsThis retrospective study analysed 212 teeth from 89 patients undergoing Invisalign treatment. Digital models were analysed after the virtual treatment plan (ST1) and after the first treatment phase (ET1) to evaluate the effective clinical rotational movement. The rotational movements of incisors, canines, and bicuspids were measured using data from the Clincheck Movements Table. ST1 and ET1 were compared to determine the actual rotational movement achieved (ST1‐ET1). The presence or absence of attachments (rectangular or optimized) on teeth was analysed. The accuracy of rotational movements among attachment types was compared using the Kruskal‐Wallis test. Multiple linear regressions were conducted with accuracy as the dependent variable and tooth type, gender, and age as predictors.ResultsOptimized attachments had the highest median accuracy (70%), followed by rectangular (65%), and without attachment (63%), with no significant differences (p = .5). There were no significant differences across age groups, genders, or tooth types. Baseline accuracy was 68.62% (95% CI: 56.03–81.20, p < .001). Age was a significant predictor (estimate = −0.30, 95% CI: −0.58 – −0.03, p = .032), indicating decreased accuracy with increasing age. The model's R2 was 0.046, with an adjusted R2 of 0.003, indicating minimal variance explained.ConclusionThe addition of attachment configurations to clear aligners improves rotational accuracy, but not significantly. Further advancements in these configurations are needed to enhance the performance of the aligners.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3