Efficacy and safety of transscleral cyclophotocoagulation versus cyclocryotherapy in the treatment of intractable glaucoma: A systematic review and meta‐analysis

Author:

Wang Shih‐Yi1ORCID,Yen Chu‐Yu1,Kuo Bo‐I12,Yen Ju‐Chuan134,Liou Shiow‐Wen125,Chen Chun‐Chen16

Affiliation:

1. Department of Ophthalmology Taipei City Hospital Taipei Taiwan

2. Department of Ophthalmology National Taiwan University Hospital Taipei Taiwan

3. Department of Education and Research Taipei City Hospital Taipei Taiwan

4. Graduate Institute of Biomedical Informatics, College of Medical Science and Technology Taipei Medical University Taipei Taiwan

5. Department of Ophthalmology Shin Kong Memorial Wu Ho‐Su Hospital Taipei Taiwan

6. Institute of Clinical Medicine National Yang‐Ming University Taipei Taiwan

Abstract

AbstractTo perform a meta‐analysis to compare the efficacy and safety of diode laser transscleral cyclophotocoagulation (TSCPC) and cyclocryotherapy (CCT) in the treatment of intractable glaucoma. Systemic searches of the Ovid MEDLINE, EMBASE, and Cochrane Library databases yielded experimental and observational comparative studies. TSCPC and CCT efficacy and safety outcomes were compared. Subgroup analyses of participant ethnicity, preoperative intraocular pressure (IOP) level, and underlying causes of glaucoma were conducted. The pooled effects were computed using the random‐effects model. The meta‐analysis included nine studies totalling 668 eyes. There was no statistically significant difference between the TSCPC and CCT groups in the IOP reduction (IOPR%), decrease in antiglaucoma medications, the operative success rate with or without medications, or retreatment rate in the efficacy analysis. In the subgroup analysis, CCT had a better IOP‐lowering effect among non‐Asian participants and a non‐inferior IOPR% to TSCPC among Asian participants. TSCPC and CCT were associated with similar rates of deterioration in visual acuity, postoperative visual analog scale, and other analysed postoperative complications in the safety analysis. In both groups, severe complications were uncommon. Diode laser TSCPC and CCT had nearly equivalent clinical efficacy in treating intractable glaucoma, while CCT demonstrated a better IOP‐lowering effect in non‐Asian. Both cyclodestructive procedures have a comparable safety profile.

Funder

Department of Health, Australian Government

Publisher

Wiley

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3