A method for measuring the angle between left atrial and left ventricular long axes using 3D echocardiography

Author:

Vekama Lasse1ORCID,Pirinen Jani1ORCID,Järvinen Vesa2,Sinisalo Juha1

Affiliation:

1. Heart and Lung Center Helsinki University Hospital and Helsinki University Helsinki Finland

2. Department of Clinical Physiology and Nuclear Medicine HUS Medical Imaging Center Helsinki Finland

Abstract

AbstractBackgroundLeft ventricle (LV) optimized views are routinely used for left atrial (LA) volume and strain measurements on 2D echocardiography. This might be a source of the error because of the variation of the angle between the left atrial and left ventricle long axes (LA‐LV angle), leading to foreshortening of the LA.MethodsWe investigated two novel parameters: the angle between the left atrial and left ventricle long axes (LA‐LV angle) and its deviation from the 4‐chamber plane. To accurately measure the angles in 3D space, these measurements were performed using 3D echocardiography. We developed a method for the measurement based on marking anatomic points of reference in the 3D echocardiogram and measuring the angles between these points. We used three types of phantoms made of wood and agar‐agar to investigate the repeatability and reproducibility of these measurements and performed measurements on human subjects.ResultsThe ultrasound measurements were in excellent agreement with the true angles of the phantoms: LA‐LV angle bias was .5 degrees (95% CI −1.8 to +2.7) in the wooden phantoms and 1.2 degrees (−.7 to +3.1) in the agar‐agar phantoms, while the angle deviation from the 4‐chamber plane was −.9 degrees (−4.3 to +4.1) in the wooden phantoms and .0 degrees (−3.3 to +3.3) in the agar‐agar phantoms. The measurements demonstrated good repeatability and reproducibility (Pearson correlation coefficients ranging from .91 to .99). The measurements from human hearts showed good repeatability (Pearson correlation was .81 for repeated LA‐LV angle measurements and .97 for repeated measurements of the deviation from the 4‐chamber plane).ConclusionThe measurement of the LA‐LV angle is a feasible tool to investigate one eventual error of 2D echocardiography.

Funder

Finska Läkaresällskapet

Publisher

Wiley

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3