Catheter-Tissue Contact Force Determines Atrial Electrogram Characteristics Before and Lesion Efficacy After Antral Pulmonary Vein Isolation in Humans
Author:
Affiliation:
1. Department of Cardiology; Parkville Victoria Australia
2. Department of Medicine, The Royal Melbourne Hospital; University of Melbourne; Parkville Victoria Australia
3. Department of Cardiology; Alfred Hospital and Baker IDI; Melbourne Australia
Funder
National Health and Medical Research Council
National Heart Foundation of Australia
Publisher
Wiley
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Link
http://onlinelibrary.wiley.com/wol1/doi/10.1111/jce.12293/fullpdf
Reference28 articles.
1. Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus;Yokoyama;Circ Arrhythm Electrophysiol,2008
2. Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model;Shah;J Cardiovasc Electrophysiol,2010
3. Effect of respiration on catheter-tissue contact force during ablation of atrial arrhythmias;Kumar;Heart Rhythm,2012
4. The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the toccata study;Reddy;Heart Rhythm,2012
5. Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: Results from the EFFICAS I study;Neuzil;Circ Arrhythm Electrophysiol,2013
Cited by 45 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Atrial electrogram amplitude variability during atrial fibrillation ablation;Journal of Cardiovascular Electrophysiology;2022-10-23
2. Augmented wide area circumferential catheter ablation for reduction of atrial fibrillation recurrence (AWARE) trial: Design and rationale;American Heart Journal;2022-06
3. Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden: The RACE-AF Randomized Controlled Trial;Circulation: Arrhythmia and Electrophysiology;2021-05
4. Radiofrequency atrial fibrillation ablation with irrigated tip catheter using remote magnetic navigation compared with conventional manual method;Journal of Interventional Cardiac Electrophysiology;2020-09-22
5. Efficacy and safety of ablation index-guided catheter ablation for atrial fibrillation: an updated meta-analysis;EP Europace;2020-08-30
1.学者识别学者识别
2.学术分析学术分析
3.人才评估人才评估
"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370
www.globalauthorid.com
TOP
Copyright © 2019-2024 北京同舟云网络信息技术有限公司 京公网安备11010802033243号 京ICP备18003416号-3