Comparison of pulsed field ablation and cryoballoon ablation for pulmonary vein isolation

Author:

Schipper Jan‐Hendrik1ORCID,Steven Daniel1,Lüker Jakob1,Wörmann Jonas1ORCID,van den Bruck Jan‐Hendrik1ORCID,Filipovic Karlo1ORCID,Dittrich Sebastian1ORCID,Scheurlen Cornelia1ORCID,Erlhöfer Susanne1,Pavel Friederike1ORCID,Sultan Arian1

Affiliation:

1. Department of Electrophysiology, Heart Center University of Cologne Köln Germany

Abstract

AbstractIntroductionPulmonary vein isolation (PVI) remains the cornerstone in the treatment of atrial fibrillation (AF). PVI using cryoballoon (CB) technology has emerged as a standard procedure in many centers. Recently, pulsed field ablation (PFA) has been introduced and used to achieve PVI. First data show high acute and favorable long‐term outcomes. So far, data comparing these new “single shot” devices are sparse. We sought to compare procedural and outcome data for first time PFA users versus CB in patients undergoing de novo PVI. Furthermore, potentially postprocedural discomfort and affection of autonomic ganglia were assessed.Methods and ResultsA retrospective analysis and comparison of all de novo PVIs with PFA and CB was performed. Furthermore, PFA PVI learning curve was evaluated. During follow‐up, repeat outpatient visits and Holter electrocardiogram were performed to analyze arrhythmia‐free survival. Discomfort analysis was obtained by prescribed analgesic medication within first 48 h after PVI. Potential changes in heart rate (HR) between baseline and at 3‐month follow‐up were evaluated. A total of 108 patients (54 PFA and 54 CB; PFA; 33 (30%) female) with paroxysmal and persistent AF were analyzed. Type of AF was comparable (Patients suffering from PAF: PFA: 16 (30%), CB: 17 (31%), p = 1.0). In 107 (99%) patients, successful PVI was achieved. Transient phrenic palsy omitted complete PVI in one CB patient. A trend for a shorter overall procedure duration was observed in the PFA group (PFA: 64.5 ± 17.5 min; CB: 73.0 ± 24.8 min; p = 0.07). Excluding LA mapping time (first 14 cases), procedure time was significantly shorter using PFA (PFA: 58.0 ± 12.5 min, CB: 73.0 ± 24.8 min, p = 0.0001). Fluoroscopy time was significantly longer for PFA (PFA: 15.3 ± 4.7 min, CB: 12.3 ± 5.3 min; p = 0.001), but significantly less contrast medium was used (PFA: 12 ± 6 mL; CB: 51 ± 29 mL, p < 0.0001). Subgroup analysis of the PFA group revealed a significant shortening of procedure duration over time (first tertile: 72.7 ± 13.5 min, second tertile: 67.3 ± 21.7 min, third tertile: 53.4 ± 9.8 min, first vs. third tertile p < 0.0001). Two cardiac tamponades occurred in the PFA group (p = 0.495), of which one was most likely related to complex transseptal puncture. In the first 48 h after PVI, the number of prescribed analgesics due to postprocedural pain was equal between both groups (PFA: 7 (13%) patients, CB: 10 (19%) patients, p = 0.598). After a FU of 273 ± 129 days, 35 of 47 patients (74%) after PFA and 36 of 50 patients (72%) after CB PVI were free of any atrial arrhythmia (HR: 0.98, p = 0.88). Only in the PFA group, a significant increase in HR 3 months after PVI was observed (pre‐PVI: 61 ± 8 beats/min, post‐PVI: 65 ± 9 beats/min, p = 0.008).ConclusionThe new PFA technology is equally effective and safe as compared to CB for complete PVI with potentially shorter procedure time and significantly less contrast medium. However, AF recurrence rates after PFA PVI seem to be comparable to CB PVI.

Publisher

Wiley

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3