Performance of the Sysmex XN‐V hematology analyzer in determining the immature platelet fraction in dogs: A preliminary study and reference values

Author:

Jornet‐Rius Oriol1ORCID,Mesalles‐Naranjo Montse1,Pastor Josep12ORCID

Affiliation:

1. Departament de Medicina i Cirurgia Animal, Facultat de Veterinària Universitat Autònoma de Barcelona Bellaterra Spain

2. Hospital Clínic Veterinari Universitat Autònoma de Barcelona Bellaterra Spain

Abstract

AbstractBackgroundImmature platelets (IPs) are newly formed platelets released into circulation that have been demonstrated as good markers of thrombopoiesis. Although many flow cytometric and fully automated‐based methods are available, the latest Sysmex XN‐V hematology analyzer for veterinary use is equipped with a specific fluorescent platelet channel (PLT‐F) that detects platelets using a platelet‐specific dye.ObjectivesThe aims of this study were to evaluate the performance of the Sysmex XSN‐1000 V in determining the IPF (immature platelet fraction) and other selected PLT‐F channel parameters and to propose IPF reference intervals (RIs) for canine blood samples.MethodsCanine EDTA blood samples were analyzed on the Sysmex XN‐1000 V to assess linearity, imprecision, carryover, stability, and the effect of platelet clumping on selected platelet parameters from the PLT‐F channel. We also reported the de novo generated RIs for the IPF in dogs.ResultsImprecision was acceptable (CV <10%) for all parameters except for the absolute IPF values (IPF#), in which the reproducibility was 12.15% for the normal‐low concentration samples. Linearity and carryover were excellent for all variables. Relative IPF values (IPF %) and IPF# remained stable for both storage conditions for up to 48 hours; however, a nonsignificant progressive increase in these parameters was observed from 12 hours at 4°C. We observed a statistical increase in IPF% and IPF# and a statistically significant decrease in PLT‐F counts after intentional in vitro platelet aggregation. RIs were generated for all reference samples (n = 69) and for samples with (n = 25) or without (n = 44) platelet clumps.ConclusionsThe performance of the new PLT‐F channel‐derived variables for dogs was excellent. Specific RIs for IPF should be used when platelet aggregates are present.

Publisher

Wiley

Subject

General Veterinary

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3