Affiliation:
1. Department of Oral and Maxillo‐facial Implantology, Shanghai Key Laboratory of Stomatology, National Clinical Research Center for Stomatology, Shanghai Ninth People's Hospital, School of Medicine Shanghai Jiaotong University Shanghai China
2. Department of Oral Surgery, Shanghai Ninth People's Hospital, College of Stomatology Shanghai Jiao Tong University School of Medicine Shanghai China
3. National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Research Unit of Oral and Maxillo‐facial Regenerative Medicine Chinese Academy of Medical Sciences Shanghai China
Abstract
AbstractObjectivesTo compare the clinical, radiographic, and immunological outcomes between one‐piece versus two‐piece zirconia abutments supported single implant crowns in the esthetic region.Materials and MethodsThe study followed a split‐mouth, double‐blind, and randomized controlled clinical design for a duration of 3 years. Twenty‐two eligible patients with 44 implants were randomly assigned to two groups: Group 1 (one‐piece zirconia abutment with zirconia base, n = 22) and Group 2 (two‐piece zirconia abutment with titanium base, n = 22). The primary outcome was the technical complication rate. Additionally, survival rates, cytokines concentrations in peri‐implant crevicular fluid (PICF), peri‐implant conditions, marginal bone loss, and pink/white esthetics score (PES/WES) were assessed as secondary outcomes.ResultsTwelve of 22 patients attended the 1‐year follow‐up (due to the COVID pandemic), and 19 patients attended the 3‐year examination. Two abutments in Group 1 were fractured after 10 and 12 months in function. Additionally, one screw loosening occurred in Group 1 at 1‐year follow‐up. The 3‐year technical complication rate was significantly higher in Group 1 than that in Group 2 (15.79% vs. 0%, p < .001). The 3‐year implant survival rate was 100% in both groups. The concentration of IFN‐γ in PICF was significantly upregulated in Group 2 (p = .018). Furthermore, the IL‐6 concentration was positively correlated with BOP% (p = .020).ConclusionsTwo‐piece zirconia abutments exhibited superior technical performance compared to one‐piece designs during a 3‐year follow‐up in the anterior region. However, further long‐term research is necessary to verify the immunological stability of two‐piece zirconia abutments.
Funder
Natural Science Foundation of Shanghai Municipality
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献