Platelet function analyzer‐200 closure curve analysis and assessment of flow‐obstructed samples

Author:

Kornya Matthew R.1ORCID,Abrams‐Ogg Anthony C. G.1ORCID,Blois Shauna L.1ORCID,Wood R. Darren2

Affiliation:

1. Department of Clinical Studies Ontario Veterinary College, University of Guelph Guelph Ontario Canada

2. Department of Pathobiology Ontario Veterinary College, University of Guelph Guelph Ontario Canada

Abstract

AbstractBackgroundThe Platelet function analyzer‐200 can determine the effect of clopidogrel in cats. Flow obstruction is an error that causes uninterpretable results. Closure curves and parameters initial flow rate (IF) and total volume (TV) are displayed by the PFA‐200 and may allow interpretation of results in cases of flow obstruction. The primary hemostasis components (PHC) are calculated values that normalize these parameters.ObjectivesTo determine if closure curves and research parameters allow detecting the effect of clopidogrel in cases of flow obstruction.MethodsA review of closure curves identified those with flow obstruction and paired analysis that did not. Non‐flow–obstructed curves were used to categorize curves with respect to clopidogrel effects. IF, TV, PHC(1), and PHC(2) were evaluated to determine if these could be used to categorize if a sample exhibited the effects of clopidogrel. Curves were visually analyzed, and characteristics identified that were more common with or without the effect of clopidogrel. Visual analysis of curves was performed by blinded observers to determine if a visual analysis was able to predict the effect of clopidogrel.ResultsAnalysis of parameters was able to predict closure or non‐closure in flow‐obstructed curves. TV, PHC(1), and PHC(2) had area under the curve of the receiver operating characteristics of 0.79, 0.79, and 0.87. Visual curve analysis was unable to predict closure, with an average accuracy of only 55%, among three reviewers. Agreement between reviewers was poor (Fleiss' Kappa 0.06).ConclusionsVisual curve analysis was unable to determine the effect of clopidogrel in flow‐obstructed samples. Numerical parameters were able to detect the effect of clopidogrel with a high degree of accuracy in flow‐obstructed samples.

Funder

OVC Pet Trust

Publisher

Wiley

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3