Comparison of two‐dimensional imaging to three‐dimensional modeling of intrahepatic portosystemic shunts using computed tomography angiography

Author:

Jackson Erin1,Markovic Lauren E.1ORCID,Perlini Michael2

Affiliation:

1. Department of Small Animal Medicine and Surgery College of Veterinary Medicine University of Georgia Athens Georgia USA

2. Department of Large Animal Medicine College of Veterinary Medicine University of Georgia Athens Georgia USA

Abstract

AbstractComputed tomography angiography (CTA) is used for the diagnosis of intrahepatic portosystemic shunts (IHPSS). When planning for transcatheter intervention, caudal vena cava (CVC) measurements are typically obtained from two‐dimensional (2D) imaging to aid in stent selection. We hypothesized that clinically applicable three‐dimensional (3D) IHPSS models can be generated, and CVC measurements will not differ between 2D images and 3D models. Computed tomography angiography datasets from client‐owned dogs with IHPSS at the University of Georgia Veterinary Teaching Hospital from 2016 to 2022 were analyzed. Materialise Mimics 25.0 and 3‐matic 17.0 were used for 3D modeling. Caudal vena cava diameters were measured in 2D dorsal and transverse planes 20 mm cranial and caudal from the shunt ostium and were compared with CVC diameters from 3D models. Length was measured in the 2D dorsal plane between midpoints of each diameter and compared to the 3D model length. Data are presented as mean (SD), and intraclass correlation coefficients were performed. Three‐dimensional models were generated for 32 IHPSS (15 right‐, 12 left‐, and five central‐divisional). Two‐dimensional dorsal and transverse area‐associated diameter measurements were 16.7 mm (5.6) and 15.5 mm (4.2) cranial; 14.9 mm (4.2) and 14.3 mm (3.7) caudal. Three‐dimensional area‐associated diameter measurements were 15.3 mm (4.4) cranial and 14.0 mm (3.6) caudal. The 2D length was 61.5 mm (7.1) compared with 3D 59.9 mm (7.2). Intraclass correlation coefficients comparing 2D and 3D diameters were all >0.80, indicating very good agreement, with good agreement (>0.60) for length. Clinically applicable 3D IHPSS models can be generated using engineering software. Measurements from 3D models are consistent with 2D planar imaging. Both 2D CTA and 3D virtual models can be utilized for preprocedural planning, depending on clinician preference.

Funder

Boehringer Ingelheim

College of Veterinary Medicine, University of Georgia

Publisher

Wiley

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3