1. Office of Science and Engineering Laboratories, Center for Devices and Radiological Health United States Food and Drug Administration Silver Spring Maryland USA
2. Department of Mechanical Engineering University of Louisville Louisville Kentucky USA
Abstract
AbstractBackgroundEulerian and Lagrangian power‐law formulations are both widely used for computational fluid dynamics (CFD) to predict flow‐induced hemolysis in blood‐contacting medical devices. Both are based on the same empirical power‐law correlation between hemolysis and the shear stress and exposure time. In the Lagrangian approach, blood damage is predicted by tracking both the stress and exposure time along a finite number of pathlines in the domain. In the Eulerian approach, a scalar transport equation is solved for a time‐linearized damage index within the entire domain. Previous analytical work has demonstrated that there is a fundamental problem with the treatment of exposure time in the Eulerian model formulation such that the only condition under which the model correctly represents the true exposure time is in a flow field with no streamwise velocity variation. However, the practical implications of this limitation have yet to be thoroughly investigated.MethodsIn this study, we demonstrate the inaccuracy of Eulerian hemolysis power‐law model predictions due to the erroneous treatment of exposure time by systematically considering four benchmark test cases with increasing degrees of flow acceleration: Poiseuille flow through a straight tube, inclined Couette flow, and flow through a converging tube with two different convergence ratios.ResultsCompared with Lagrangian predictions, we show that, as flow acceleration becomes more pronounced, the resultant inaccuracy in the Eulerian predictions increases. For the inclined Couette flow case, there is a small degree of flow acceleration that yields a discrepancy in the range of 10% between Lagrangian and Eulerian predictions. For flows with a larger degree of acceleration, as occurs in the converging tube flow cases, the discrepancy is considerably larger (up to 257%).ConclusionThe inaccuracy of hemolysis predictions due to the erroneous treatment of exposure time in the Eulerian power‐law model can be significant when there is streamwise velocity variation in the flow field. These results may partially explain the extremely large variability in CFD hemolysis predictions reported in the literature between Lagrangian and Eulerian models.
Subject
Biomedical Engineering,General Medicine,Biomaterials,Medicine (miscellaneous),Bioengineering
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献