Practical implications of the erroneous treatment of exposure time in the Eulerian hemolysis power law model

Author:

Faghih Mohammad M.1,Craven Brent A.1ORCID,Sharp M. Keith2ORCID

Affiliation:

1. Office of Science and Engineering Laboratories, Center for Devices and Radiological Health United States Food and Drug Administration Silver Spring Maryland USA

2. Department of Mechanical Engineering University of Louisville Louisville Kentucky USA

Abstract

AbstractBackgroundEulerian and Lagrangian power‐law formulations are both widely used for computational fluid dynamics (CFD) to predict flow‐induced hemolysis in blood‐contacting medical devices. Both are based on the same empirical power‐law correlation between hemolysis and the shear stress and exposure time. In the Lagrangian approach, blood damage is predicted by tracking both the stress and exposure time along a finite number of pathlines in the domain. In the Eulerian approach, a scalar transport equation is solved for a time‐linearized damage index within the entire domain. Previous analytical work has demonstrated that there is a fundamental problem with the treatment of exposure time in the Eulerian model formulation such that the only condition under which the model correctly represents the true exposure time is in a flow field with no streamwise velocity variation. However, the practical implications of this limitation have yet to be thoroughly investigated.MethodsIn this study, we demonstrate the inaccuracy of Eulerian hemolysis power‐law model predictions due to the erroneous treatment of exposure time by systematically considering four benchmark test cases with increasing degrees of flow acceleration: Poiseuille flow through a straight tube, inclined Couette flow, and flow through a converging tube with two different convergence ratios.ResultsCompared with Lagrangian predictions, we show that, as flow acceleration becomes more pronounced, the resultant inaccuracy in the Eulerian predictions increases. For the inclined Couette flow case, there is a small degree of flow acceleration that yields a discrepancy in the range of 10% between Lagrangian and Eulerian predictions. For flows with a larger degree of acceleration, as occurs in the converging tube flow cases, the discrepancy is considerably larger (up to 257%).ConclusionThe inaccuracy of hemolysis predictions due to the erroneous treatment of exposure time in the Eulerian power‐law model can be significant when there is streamwise velocity variation in the flow field. These results may partially explain the extremely large variability in CFD hemolysis predictions reported in the literature between Lagrangian and Eulerian models.

Publisher

Wiley

Subject

Biomedical Engineering,General Medicine,Biomaterials,Medicine (miscellaneous),Bioengineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3