Analysis of the Ability of a Distal Tibial Anatomical Locking Plate to Capture the Distal Tibial Fragments in Patients with Pilon Fractures

Author:

Liu Jun‐Hong1,Zhang Qiang1,Wei Guo‐Hua1,Liu Liang1,Mu Xin1,Li Mao‐Lin1,Wu Zong‐De1ORCID

Affiliation:

1. Foot and Ankle Department 1 Sichuan Orthopaedic Hospital Chengdu China

Abstract

ObjectiveAlthough pilon fractures are rare in clinical practice, they are difficult to treat because of their complexity. Effective fixation of the fracture fragment is the key to the treatment of pilon fractures. Plate osteosynthesis is common clinically, but there are many types of plates and the evaluation of the effect of fixation plates is not comprehensive.This study attempted to compare the capture effect of different fixation plates on the fracture fragments based on 3D modeling and fine distinctions of fracture fragments.MethodsThe computed tomography (CT) images before treatment of 127 patients with pilon fractures from January 2019 to December 2021 were retrospectively collected. The fracture lines were mapped and digitally displayed as 3D images using MIMICS 21 software. APLUS distal tibia anatomical locking plate (Plate A) and ZIMMER distal tibia anatomical plate (Plate B) were placed on a pseudo‐bone model and CT scans were used to determine the number of screws in the major and minor fragments of pilon fractures. The frequency of the two plates capturing the fracture fragments was recorded.ResultsUnder Assumption 1 or 2, Plate A performed significantly better than Plate B in capturing the major, Chaput, Volkmann, medial malleolus, and die‐punch fracture fragments. Plate A captured markedly more minor fragments than Plate B under Assumption 2 but was not significantly different from Plate B under Assumption 1. Plate A or Plate B showed no obvious difference between major and minor capture rates under the same assumption, and A1 or B1 showed a markedly higher capture rate compared with A2 or B2. In addition, there was a significant positive correlation between the major capture rate and the major fragments in B1, and a significant negative correlation between the minor capture rate and the minor fragments in Plates A and B. However, there was no correlation between the major capture rate of Plate A and the major fragments.ConclusionThe APLUS distal tibial anatomical locking plate is superior to the ZIMMER distal tibia anatomical plate in the ability to capture distal tibial fragments in pilon fracture cases.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3