Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs

Author:

Brans Marleen1ORCID,Marynissen Sofie1ORCID,Mortier Femke1ORCID,Duchateau Luc2,Daminet Sylvie1ORCID,Paepe Dominique1ORCID

Affiliation:

1. Small Animal Department, Faculty of Veterinary Medicine Ghent University Ghent Belgium

2. Department of Morphology, Imaging, Orthopedics, Rehabilitation, and Nutrition Ghent University Ghent Belgium

Abstract

AbstractBackgroundStability of serum symmetric dimethylarginine (sSDMA) during short‐ and long‐term storage has not been assessed for the immunoassay of the Point‐of‐Care IDEXX Catalyst DX (POC) analyzer and the Enzyme Multiplied Immunoassay Technique of IDEXX commercial laboratory (CL). Also, the agreement between both analyzers is questioned.ObjectivesTo determine (a) the effect of storage time and temperature on sSDMA measured by POC and CL; (b) the agreement between sSDMA measured by POC and CL; and (c) the imprecision of the POC.AnimalsSerum of cats (n = 17) and dogs (n = 18) with a range of SDMA concentrations (6 to >100 μg/dL).MethodsBased on an equivalence trial with predefined equivalence range (−3.0 to +3.0 μg/dL) and using T0 as baseline, stability was evaluated after 24 hours at 22°C and 4°C (POC); after 7 days at 4°C (POC and CL) and after 10 and 24 months at −24°C and −80°C (CL). Bland‐Altman plots enabled method comparison. Imprecision of the POC was assessed by duplicate sSDMA measurements at T0.ResultsThe POC analyzer produced equivalent sSDMA measurements if samples were stored for 24 hours at 4°C (95% confidence interval [CI]: −2.5‐2.0 μg/dL), but not when stored for 24 hours at room temperature (RT; 95% CI: −4.1 to 0.5 μg/dL) or after 7 days at 4°C (95% CI: −3.6‐1.0 μg/dL). The CL analyzer was less affected by preanalytical variation with clinically similar results obtained when samples were stored for 7 days at 4°C (95% CI: −2.2 to 2.4 μg/dL) and for at least 24 months at −24°C (95% CI: −1.7 to 2.9 μg/dL) and −80°C (95% CI: −1.5 to 3 μg/dL). A relevant mean difference of −2.3 μg/dL between both analyzers was found. Duplicate POC measurements were equivalent (95% CI: −2.6 to 2.0 μg/dL).ConclusionsDelayed analysis may significantly change sSDMA depending on storage and measurement conditions. Interchangeable use of assays should be done with caution because analytical variation could be interpreted as clinically relevant change.

Publisher

Wiley

Subject

General Veterinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3