Development of novel tracers for sentinel node identification in cervical cancer

Author:

Kodama Keisuke1ORCID,Tateishi Chuya2,Oda Tsuyoshi2,Cui Lin1,Kuramoto Kazutaka1,Yahata Hideaki1,Okugawa Kaoru1,Maenohara Shoji1,Yagi Hiroshi1,Yasunaga Masafumi1,Onoyama Ichiro1,Asanoma Kazuo1,Mori Takeshi2,Katayama Yoshiki23,Kato Kiyoko1

Affiliation:

1. Department of Obstetrics and Gynecology Graduate School of Medical Sciences, Kyushu University Fukuoka Japan

2. Department of Chemistry and Biochemistry Graduate School of Systems Life Sciences, Graduate School of Engineering, Kyushu University Fukuoka Japan

3. Department of Biomedical Engineering Chung Yuan Christian University Taoyuan City Taiwan

Abstract

AbstractIndocyanine green (ICG) with near‐infrared (NIR) fluorescence imaging is used for lymphatic mapping. However, binding of ICG to blood proteins like serum albumin can shorten its retention time in sentinel lymph nodes (SLNs). Here, we investigated the efficacy and safety of a new fluorescence tracer comprising phytate and liposome (LP)‐encapsulated ICG. Coadministration of phytate with LP containing phosphatidic acid promotes chelation mediated by Ca2+ in bodily fluids to enhance SLN retention. Uniformly sized LPs (100 nm) encapsulating ICG under conditions that minimized fluorescence self‐quenching during storage were produced. We analyzed the behavior of the new tracer (ICG‐phytate‐LP) and control tracers (ICG and ICG‐LP) in the lymphatic flow of mice in terms of lymph node retention time. We also tested lymphatic flow and safety in pigs that have a more human‐like lymphatic system. LPs encapsulating stabilized ICG were successfully prepared. Mixing LP with phytate in the presence of Ca2+ increased both the particle size and negative surface charge. In mice, ICG‐phytate‐LP had the best lymph node retention, with a fluorescence intensity ratio that increased over 6 h and then decreased slowly over the next 24 h. In pigs, administration of ICG and ICG‐phytate‐LP resulted in no death or weight loss. There were no obvious differences between blood test results for the ICG and ICG‐phytate‐LP groups, and the overall safety was good. ICG‐phytate‐LP may be a useful new tracer for gynecological cancers that require time for lymph node identification due to a retroperitoneal approach.

Funder

Japan Society for the Promotion of Science

Publisher

Wiley

Subject

Cancer Research,Oncology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3