A Novel Deformity Correction Manipulation System for Better Correction of Large Thoracic Scoliosis

Author:

Huang Yong1ORCID,Zhu Ce1,Wang Yongliang2,Feng Ganjun1,Liu Limin1ORCID

Affiliation:

1. Department of Orthopedic Surgery and Orthopedic Research Institute, West China Hospital Sichuan University Chengdu China

2. Department of Orthopedic Surgery Pangang Group General Hospital Panzhihua China

Abstract

ObjectiveTreating patients with large thoracic scoliosis (between 70° and 100°) poses technical challenges, particularly with traditional correction techniques (TCT). To address this, we developed a novel deformity correction manipulation system (DCMS) aimed at reducing surgical complexity and trauma. This study aims to assess the safety and effectiveness of DCMS in treating large thoracic scoliosis.MethodsFrom January 2016 to June 2021, 76 patients with large thoracic scoliosis were included in this retrospective study. The patients were divided into two groups: DCMS (n = 34) and TCT (n = 42). Basic patient data including age at surgery, sex, etiology, Risser sign, flexibility of the main thoracic curve, instrumented levels, number of screws, duration of hospital stay, and follow‐up time were collected and analyzed. Radiographic and clinical outcomes, as measured by various radiographic parameters and Scoliosis Research Society‐30 (SRS‐30) scores, were retrospectively analyzed and compared between the two groups. Adverse events were also documented. Statistical analyses were performed using two‐tailed independent t‐tests, chi‐square tests, and Fisher's exact test.ResultsThe DCMS group exhibited significantly shorter operative times, reduced blood loss, and shorter hospital stays compared to the TCT group. However, there were no significant differences between the two groups in terms of age at surgery, sex, etiology, Risser sign, flexibility of the main curve, instrumented levels, number of screws, and follow‐up time. While preoperative major curves were statistically similar between the two groups, the DCMS group achieved a superior correction rate compared to the TCT group (74.2% ± 8.8% vs 68.1% ± 10.5%). No significant differences were observed in other radiographic parameters, SRS‐30 scores, or the incidence of adverse events.ConclusionThe application of DCMS resulted in shorter operative times, reduced blood loss, shorter hospital stays, and greater curve correction compared to TCT. DCMS proves to be a safe and effective technique for treating large thoracic curves.

Funder

National Natural Science Foundation of China

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3