First clinical experience of a ring‐configured cadmium zinc telluride camera: A comparative study versus conventional gamma camera systems

Author:

Cerić Andelius Irma1ORCID,Minarik David12,Persson Eva34,Mosén Henrik34,Valind Kristian23ORCID,Trägårdh Elin23ORCID,Oddstig Jenny12

Affiliation:

1. Radiation Physics, Skåne University Hospital Lund/Malmö Sweden

2. Department of Translational Medicine and Wallenberg Centre of Molecular Medicine Lund University Malmö Sweden

3. Department of Clinical Physiology and Nuclear Medicine Skåne University Hospital Lund/Malmö Sweden

4. Department of Clinical Sciences Lund University Lund Sweden

Abstract

AbstractBackgroundA novel semiconductor cadmium zinc telluride (CZT) gamma camera system using a block sequential regularized expectation maximization (BSREM) reconstruction algorithm is now clinically available. Here we investigate how a multi‐purpose ring‐configurated CZT system can be safely applied in clinics and describe the initial optimization process.MethodSeventy‐six patients (bone‐, cardiac‐ and lung scan) were scanned on a conventional gamma camera (planar and/or single‐photon emission computed tomography [SPECT]/SPECT‐CT) used in clinical routine and on the ring‐configurated CZT camera Starguide (GE Healthcare). These data were used to validate and optimize the Starguide system for routine clinical use.ResultsComparable image quality for the Starguide system, to that of the conventional gamma camera, was achieved for bone scan (4 min/bed position [BP] using a relative difference prior [RDP] with gamma 2 and beta 0.4, along with 10 iterations and 10 subsets), cardiac scan (8 min [stress] and 3 min 20 s [rest] using median root prior [MRP] with beta 0.07 non attenuation corrected and 0.008 attenuation corrected and 50 interations and 10 subsets for both stress and rest) and lung scan (10 min [vent] and 5 min [perf] using RDP with gamma 0.5 and beta 0.03 [vent] and 0.02 [perf] and 20 interations and 10 subsets for both vent and perf).ConclusionsIt was possible to transition from a conventional gamma camera to the Starguide system as part of the clinical routine, with acceptable image quality. Images from the Starguide system were deemed to be at least as good as those from a conventional gamma camera.

Publisher

Wiley

Subject

Physiology (medical),General Medicine,Physiology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3