Diagnostic performance of fluorescence microscopy with a tetramethylrhodamine isothiocyanate filter in identifying renal amyloidosis

Author:

Pinedo Pichilingue Aranza1ORCID,Thayyil Abdullah1,Dai Dao‐Fu1,Rastogi Prerna1ORCID

Affiliation:

1. Department of Pathology University of Iowa Hospitals and Clinics Iowa City IA USA

Abstract

BackgroundRenal amyloidosis (RA) has a worldwide incidence of 5–13 cases per million person‐years and is expected to rise in upcoming years due to growing awareness, plus improvement of diagnostic modalities. Diagnosing RA remains challenging, especially when encountering very small, focal, or early amyloid deposits. Since delays in diagnosis portends poor prognosis, high morbidity, and mortality, it is crucial to evaluate the performance of commonly used diagnostic modalities. This is the first study that presents a full picture of the diagnostic performance of fluorescence microscopy (FM) with a tetramethylrhodamine isothiocyanate (TRITC) filter to diagnose RA in general and stratified by compartments.Materials and methodsA retrospective double‐blind diagnostic accuracy study of FM‐TRITC filter was performed. The presence or absence of amyloid in the vascular, interstitial, and glomerular compartments was established in 316 representative Congo red‐stained core biopsies with an FM‐TRITC filter. This was contrasted with polarized microscopy (PM) showing apple‐green birefringence as the gold standard. Sensitivity, specificity, positive and negative predictive values, likelihood ratios, and the receiver operating characteristic (ROC) curve were obtained using STATA13.ResultsThe prevalence of RA was 6.01%, comparable with that reported in the literature. Reciprocity with regard to the location and pattern of fluorescence and birefringence between the two diagnostic modalities was seen. The FM‐TRITC filter has a sensitivity of 100%, specificity of 97.64%, and a positive and negative predictive value of 73.08% and 100%, respectively. The positive likelihood ratio was 42.37, and the negative was 0.00. Overall accuracy was 97.78%. The area under the ROC curve was 0.98. The Diagnostic performance of the FM‐TRITC filter stratified by compartments is shown in Table 1. The area under the ROC curve was 0.99, 0.98, and 0.99 for the vascular, interstitial, and glomerular compartment, respectively. All patients with RA (n = 19) were correctly identified; this included one new case, one case with small and focal amyloid, and two early cases with less dense amyloid where birefringence was ambiguous by PM.DiscussionThe FM‐TRITC filter is a highly accurate, sensitive, specific, with excellent predictive values, time‐efficient, easy to perform, and suitable to reproduce diagnostic modality for RA. It can accurately rule out RA in all compartments, and in most cases concomitant use of PM should not be indispensable. The diagnosis of vascular, interstitial, and glomerular amyloid deposits can be done using only the FM‐TRITC filter with Congo red‐stained slides. Exceptionally, a few cases of interstitial amyloidosis could be overdiagnosed due to interferences (e.g. artefacts), these cases could be further assessed with a second diagnostic modality if positive fluorescence is seen. Routine use of the FM‐TRITC filter can aid in the diagnosis of early RA, even when the deposits are inconspicuous by PM.

Publisher

Wiley

Subject

General Medicine,Histology,Pathology and Forensic Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3