Mid‐ to Long‐term Follow‐up of Severe Acetabular Bone Defect after Revision Total Hip Arthroplasty Using Impaction Bone Grafting and Metal Mesh

Author:

Yang Chao1,Zhu Kechao1,Dai Huiyong1,Zhang Xianlong1,Wang Qiaojie1,Wang Qi1ORCID

Affiliation:

1. Department of Orthopaedics Shanghai Jiao Tong University Affiliated Sixth People's Hospital Shanghai China

Abstract

ObjectiveIn revision total hip arthroplasty (THA), reconstruction of severe acetabular bone defect continues to be problematic for orthopedic surgeons. This study reports the mid‐ to long‐term survivorship, radiological outcomes, and complications of impaction bone grafting (IBG) and metal mesh with a cemented acetabular component in the reconstruction of severe acetabular bone defects in revision THA.MethodsThis retrospective consecutive study included 26 patients (29 hips: type II B, four; type II C, three; type III A, 10; and type III B, 12) who underwent revision THA, which was performed using IBG and metal mesh, between 2007 and 2014 in our institution. All patients were followed up regularly for clinical and radiographical assessments. Migration and loosening of prosthesis graft integration and complications were observed and analyzed. Survival analysis was performed using a Kaplan–Meier survival analysis.ResultsAt the time of revision, 75.9% of the hips (22 hips) were classified as type III bone defects. The average follow‐up period was 9.4 ± 2.8 (range, 2.4–14.0) years. Of the 29 hips, four hips (13.8%) were assessed as clinical failures; at the last follow‐up, two had undergone re‐revision THA, and two had not been scheduled for re‐revision THA despite radiological failure of the acetabular component. Among them, three clinical failures (10.3%) were due to aseptic loosening, and one (3.4%) was due to infection. Radiographic evaluation showed bone graft integration in all hips during the follow‐up. The Kaplan–Meier survivorship analysis revealed an acetabular reconstruction survival rate of 86.5% (95% confidence interval, 61.4%–95.7%) at 10 years.ConclusionIBG and metal mesh with a cemented acetabular component for revision THA is an effective technique for treating severe acetabular bone defects, with effective mid‐ to long‐term outcomes due to the solid reconstruction of the acetabular bone defect and restoration of the hip rotation center.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3