Impact of artificial intelligence arrhythmia mapping on time to first ablation, procedure duration, and fluoroscopy use

Author:

Fox Sutton R.12,Toomu Avinash1,Gu Kelly12,Kang Jessica1,Sung Kevin12,Han Frederick T.12,Hoffmayer Kurt S.12,Hsu Jonathan C.1,Raissi Farshad1,Feld Gregory K.1ORCID,McCulloch Andrew D.13,Ho Gordon12,Krummen David E.12ORCID

Affiliation:

1. Department of Medicine University of California San Diego La Jolla California USA

2. Department of Medicine Veterans Affairs San Diego Healthcare System San Diego California USA

3. Department of Biomedical Engineering University of California San Diego La Jolla California USA

Abstract

AbstractIntroductionArtificial intelligence (AI) ECG arrhythmia mapping provides arrhythmia source localization using 12‐lead ECG data; whether this information impacts procedural efficiency is unknown. We performed a retrospective, case‐control study to evaluate the hypothesis that AI ECG mapping may reduce time to ablation, procedural duration, and fluoroscopy.Materials and MethodsCases in which system output was used were retrospectively enrolled according to IRB‐approved protocols at each site. Matched control cases were enrolled in reverse chronological order beginning on the last day for which the technology was unavailable. Controls were matched based upon physician, institution, arrhythmia, and a predetermined complexity rating. Procedural metrics, fluoroscopy data, and clinical outcomes were assessed from time‐stamped medical records.ResultsThe study group consisted of 28 patients (age 65 ± 11 years, 46% female, left atrial dimension 4.1 ± 0.9 cm, LVEF 50 ± 18%) and was similar to 28 controls. The most common arrhythmia types were atrial fibrillation (n = 10), premature ventricular complexes (n = 8), and ventricular tachycardia (n = 6). Use of the system was associated with a 19.0% reduction in time to ablation (133 ± 48 vs. 165 ± 49 min, p = 0.02), a 22.6% reduction in procedure duration (233 ± 51 vs. 301 ± 83 min, p < 0.001), and a 43.7% reduction in fluoroscopy (18.7 ± 13.3 vs. 33.2 ± 18.0 min, p < 0.001) versus controls. At 6 months follow‐up, arrhythmia‐free survival was 73.5% in the study group and 63.3% in the control group (p = 0.56).ConclusionUse of forward‐solution AI ECG mapping is associated with reductions in time to first ablation, procedure duration, and fluoroscopy without an adverse impact on procedure outcomes or complications.

Funder

American Heart Association

National Institutes of Health

Australian Historical Association

Saving Tiny Hearts Society

Publisher

Wiley

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3