Performance of handheld ultrasound devices in diagnosis of pulmonary hypertension and right heart dysfunction in ICU patients

Author:

Dayıoğlu Mürüvvet1ORCID,Gürsel Gül2,Özercan Seçil1,Aydın Eda Macit1,Nadastepe Özge1

Affiliation:

1. Critical Care Fellowship Program Gazi University School of Medicine Ankara Turkey

2. Department of Pulmonary Disease Division of Critical Care Medicine Gazi University School of Medicine Ankara Turkey

Abstract

AbstractAimThe use of handheld ultrasonography devices (HHUD) has increased recently but there are limited data about their performance in the evaluation of right heart dysfunction (RHD) and pulmonary hypertension (PHT). The aim of the study is to compare the performance of a HHUD with a conventional ultrasound device (CUD) in assessing PHT and RHD.MethodsThis single‐center prospective study was performed in a seven‐bed teaching hospital intensive care unit (ICU). PHT and RHD criteria were compared by HHUD and CUD. Additional PHT criteria and right ventricle (RV) systolic and diastolic dysfunction criteria were also measured.ResultsForty‐six patients were included in the study. There was no significant difference between the imaging rates and mean values of the parameters measured by both devices. When the positivity rates for additional PHT parameters and RHD criteria were compared, there were no significant differences between the devices. In Bland‐Altman's analysis, there was good agreement and there was no bias between the measurements of the two devices but left ventricular end‐systolic eccentricity index (LVSEI), right atrium area (RAA), and pulmonary artery diameter (PAD). Ninety percent of the patients had PHT probability, of whom 43% had a low, 37% had intermediate and 10% had a high probability of PHT. Ninety‐two percent of the patients had RHD and there was no significant difference between the devices in the diagnosis of RHD (p = .212). When RV systolic and diastolic dysfunction evaluations of the devices were compared according to the British Society of Echocardiography (BSE) criteria there was no significant difference between the devices’ measurements in the evaluation of systolic and diastolic function.ConclusionThe imaging and measurement capabilities of the HHUDs for PHT and RHD parameters were similar to CUDs, and considering the inconsistent parameters, the HHUD can be useful in diagnosing these problems.

Publisher

Wiley

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3