Factors determining the resection ability of snares in cold snare polypectomy: Construction of an ex vivo model for accurately evaluating resection ability

Author:

Hirose Ryohei12,Yoshida Takuma1,Yoshida Naohisa1ORCID,Yamauchi Katsuma12,Miyazaki Hajime12,Watanabe Naoto12,Bandou Risa3,Inoue Ken1ORCID,Ikegaya Hiroshi3,Nakaya Takaaki2,Itoh Yoshito1

Affiliation:

1. Department of Molecular Gastroenterology and Hepatology Graduate School of Medical Science, Kyoto Prefectural University of Medicine Kyoto Japan

2. Department of Infectious Diseases Graduate School of Medical Science, Kyoto Prefectural University of Medicine Kyoto Japan

3. Department of Forensic Medicine Graduate School of Medical Science, Kyoto Prefectural University of Medicine Kyoto Japan

Abstract

ObjectivesCold snare polypectomy (CSP)‐dedicated snares (DSs) may have a higher resection ability than conventional snares. However, a model that can accurately and objectively evaluate and compare the resection ability of each snare has yet to be determined, and characteristics of snare parts that increase resection ability remain unknown. Therefore, we elucidated DSs' resection ability and all characteristics of the parts required for acquiring high resection ability.MethodsAn ex vivo model for evaluating resection ability was generated using human colons obtained from forensic autopsy specimens. The force required to resect a 15 mm wide human colonic mucosa (FRR) was measured using this model; if the FRR is small, the resection ability is high. Next, after measuring the stiffness of each snare part, the correlation between the stiffness and resection ability was analyzed.ResultsThe force required to resect using SnareMaster Plus, Micro‐Tech Cold Snare, Captivator Cold, Exacto Cold Snare, or Captivator II was 13.6 ± 1.0, 12.5 ± 1.2, 7.4 ± 1.2, 6.5 ± 1.0, and 28.7 ± 3.7 N, respectively. All DSs had significantly lower FRR than the conventional snare (Captivator II) and had higher resection ability (P < 0.001). A negative correlation was found between FRR and sheath or wire spindle stiffness, with correlation coefficients of 0.72 (P = 0.042) or 0.94 (P < 0.001), respectively. Moreover, 1 × 7 type wire rings had significantly higher friction coefficients than 1 × 3 type wire rings (P < 0.002).ConclusionSheath and wire spindle stiffness should be increased to increase resection ability; 1 × 7 type wire rings may be suitable for CSP‐snare parts.

Publisher

Wiley

Subject

Gastroenterology,Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3