Quantitative comparison of immunohistochemical HER2‐low detection in an interlaboratory study

Author:

Hempenius Maaike Anna1ORCID,Eenkhoorn Maran A2,Høeg Henrik3,Dabbs David J4ORCID,van der Vegt Bert1ORCID,Sompuram Seshi R5,‘t Hart Nils A2

Affiliation:

1. Department of Pathology and Medical Biology University of Groningen, University Medical Center Groningen Groningen the Netherlands

2. Department of Pathology Isala Klinieken Zwolle the Netherlands

3. Visiopharm A/S Hørsholm Denmark

4. PreludeDx Laguna Hills CA USA

5. Boston Cell Standards Inc. Boston MA USA

Abstract

AimsRecently, human epidermal growth factor 2 (HER2)‐low (i.e. HER2 score 1+ or 2+ without amplification) breast cancer patients became eligible for trastuzumab–deruxtecan treatment. To improve assay standardisation and detection of HER2‐low in a quantitative manner, we conducted an external quality assessment‐like study in the Netherlands. Dynamic range cell lines and immunohistochemistry (IHC) calibrators were used to quantify HER2 expression and to assess interlaboratory variability.Methods and resultsThree blank slides with a dynamic range cell line and an IHC calibrator were stained with routine HER2 assays by 35 laboratories. Four different antibody clones were used: 19 (54.3%) 4B5, six (17.1%) A0485, five (14.3%) DG44 (HercepTest) and five (14.3%) SP3. Laboratories used two different detection kits for 4B5 assays: 14 (73.7%) ultraView and five (26.3%) OptiView. Variability of HER2 expression in cell lines, measured with artificial intelligence software, was median (min–max) = negative core 0.5% (0.0–57.0), 1+ core 4.3% (1.6–71.3), 2+ core 42.8% (30.4–92.6) and 3+ core 96.2% (91.8–98.8). The calibrators DG44 and 4B5 OptiView had the highest analytical sensitivity, closely followed by 4B5 ultraView. SP3 was the least sensitive. Calibrators of A0485 assays were not analysable due to background staining.ConclusionsAs assays were validated for detecting HER2‐amplified tumours, not all assays and antibodies proved suitable for HER2‐low detection. Some tests showed distinct expression in the negative cell line. Dynamic range cell line controls and quantitative analysis using calibrators demonstrated more interlaboratory variability than commonly appreciated. Revalidation of HER2 tests by laboratories is needed to ensure clinical applicable HER2‐low assays.

Funder

AstraZeneca

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3