Influence of drilling sequence and guide‐hole design on the accuracy of static computer‐assisted implant surgery in extraction sockets and healed sites—An in vitro investigation

Author:

Raabe Clemens1ORCID,Dulla Fabrice Alain1,Yilmaz Burak234,Chappuis Vivianne1ORCID,Abou‐Ayash Samir2

Affiliation:

1. Department of Oral Surgery and Stomatology, School of Dental Medicine University of Bern Bern Switzerland

2. Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine University of Bern Bern Switzerland

3. Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine University of Bern Bern Switzerland

4. Division of Restorative and Prosthetic Dentistry The Ohio State University College of Dentistry Columbus Ohio USA

Abstract

AbstractObjectivesTo evaluate the effect of drilling sequence, guide‐hole design, and alveolar ridge morphology on the accuracy of implant placement via static computer‐assisted implant surgery (sCAIS).Materials and MethodsStandardized maxillary bone models including single‐tooth gaps with fresh extraction sockets or healed alveolar ridge morphologies were evaluated in this study. Implants were placed using different drilling sequences (i.e., complete [CDS] or minimum [MDS]), and guide‐hole designs (i.e., manufacturer's sleeve [MS] or sleeveless [SL] guide‐hole designs). The time for implant placement via sCAIS procedures was also recorded. The angular, crestal, and apical three‐dimensional deviations between planned and final implant positions were digitally obtained. Statistical analyses were conducted by a non‐parametric three‐way ANOVA (α = .05).ResultsBased on a sample size analysis, a total of 72 implants were included in this study. Significantly higher implant position accuracy was found at healed sites compared to extraction sockets and in SL compared to MS guide‐hole design in angular, crestal, and apical 3D deviations (p ≤ .048). A tendency for higher accuracy was observed for the CDS compared to the MDS, although the effect was not statistically significant (p = .09). The MDS required significantly shorter preparation times compared with CDS (p < .0001).ConclusionImplant placement via sCAIS resulted in higher accuracy in healed sites than extraction sockets, when using SL compared to MS guides, and tended to be more accurate when using CDS compared to MDS. Therefore, even though surgery time was shorter with MDS, its use should be limited to strictly selected cases

Publisher

Wiley

Subject

Oral Surgery

Reference35 articles.

1. Influence of Metal Guide Sleeves on the Accuracy and Precision of Dental Implant Placement Using Guided Implant Surgery: An In Vitro Study

2. Cortical bone drilling and thermal osteonecrosis

3. Optimizing esthetics for implant restorations in the anterior maxilla: Anatomic and surgical considerations;Buser D.;The International Journal of Oral & Maxillofacial Implants,2004

4. Effectiveness of Contour Augmentation with Guided Bone Regeneration: 10-Year Results

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献