Radiation from the equine perineal region is low compared with the elbow and head 24 hours after bone scintigraphic examination

Author:

Marcelino Leticia1ORCID,Falk Emma2,Johansson Jessica1,Rydén Jesper3,Uhlhorn Margareta1,Ley Charles J.2

Affiliation:

1. Department of Diagnostic Imaging University Animal Hospital Swedish University of Agricultural Sciences Uppsala Sweden

2. Department of Clinical Sciences Swedish University of Agricultural Sciences Uppsala Sweden

3. Department of Energy and Technology Swedish University of Agricultural Sciences Uppsala Sweden

Abstract

AbstractThe timing of follow‐up radiography and ultrasound in horses that undergo skeletal scintigraphy for lameness investigation varies internationally and between equine hospitals. The prospective, one‐group, pretest, posttest study aimed to estimate radiation levels from horses three and 24 h after injection of hydroxydiphosphonate labeled with metastable technetium (99mTc‐HDP) and investigate which anatomical locations of the horse had higher radiation levels. Included were 46 horses referred for lameness investigation between June and December 2021. Radiation levels from the horse surface were measured using an electronic device from six anatomical locations (head, elbow, dorsum, ventrum, stifle, and perineum) at two time points and adjusted to three and 24 h after injection of 99mTc‐HDP using the radioactive decay law. The radiation measured was significantly different in the various locations of the horses for both time points. At 3 h after injection of 99mTc‐HDP, the ventrum had the highest radiation dose. At 24 h, the radiation emitted from the perineal region was significantly lower (P < .0001) than from the elbow and head, which had the highest values. There was a negative correlation between age and the radiation detected at 24 h postinjection (P = .02). Radiation from the perineal region was low compared with other regions of the horse 24 h postscintigraphy. Additional care should be taken around the ventrum area during the scintigraphy examination and around the elbow and head at 24 h postscintigraphy to minimize radiation to personnel.

Publisher

Wiley

Reference38 articles.

1. Advances in Nuclear Medicine

2. Evaluation of the diagnostic accuracy of skeletal scintigraphy in lame and poorly performing sports horses

3. GardinerJ. Nuclear Scintigraphy.School of Veterinary Medicine. Published June 6 2018. Accessed February 7 2023.https://www.vetmed.ucdavis.edu/hospital/diagnostic‐imaging‐services/nuclear‐scintigraphy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3