Use of External Uterine Electromyography Across Stage I Labor

Author:

Benfield Rebecca1ORCID,Newton Edward R.2

Affiliation:

1. School of Nursing University of Nevada, Las Vegas Las Vegas Nevada

2. Obstetrics and Gynecology, Brody School of Medicine East Carolina University Greenville North Carolina

Abstract

IntroductionHighly sensitive, external uterine electromyography (EMG) measures myometrial electrical activity and is noninvasive compared with the clinical intrauterine pressure catheter. Most experimental studies have measured EMG in 30‐minute epochs, limiting the utility of this instrumentation in intrapartum clinical practice. To test proof of concept, surface uterine EMG contraction activity was continuously collected throughout the first stage of labor from healthy women at term gestation with (n = 3) and without (n = 1) epidural or combined spinal‐epidural analgesia for a maximal length of 11 hours and 24 minutes.MethodsEMG activity was recorded concurrently with tocodynamometer (toco) signals, using a pair of electrodes on the left and right sides of the maternal umbilicus with grounds attached to both hips of the reclining woman in labor. The preamplifier cutoff frequency settings were appropriate to monitor smooth muscle contraction in labor, with the analog high‐pass filter set at 0.05 Hz and the low‐pass filter at 1.50 Hz. Signals were sampled at 100 Hz, transmitted to a computer, and visualized by Chart 4.2 software. EMG data from epochs at baseline, during the pre‐epidural fluid bolus and at the 60‐minute post‐epidural test dose, and at 3, 5, 6, and 8 cm dilatation were analyzed for burst power spectrum peak frequency (Hz), burst power spectrum amplitude (mV2), and burst duration (seconds).ResultsUterine EMG contractile bursts were preceded and followed by a stable baseline and coincided with toco contractions. Movement artifacts were negligible, and large movement artifacts were easily distinguishable. The EMG bursts and toco contractions remained clearly identifiable, even when one woman without epidural analgesia stood beside the bed laboring for approximately 10 minutes. Burst spectral components fell within the expected 0.34‐to‐1.00 Hz range for term labor.DiscussionHigh‐quality data demonstrate that EMG instrumentation effectively and accurately measures uterine contraction parameters across the first stage of term labor.

Publisher

Wiley

Subject

Maternity and Midwifery,Obstetrics and Gynecology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3