Improving safety in anesthetized patients undergoing magnetic resonance imaging—Concept of time‐out in the MRI suite and measures to improve adherence to time‐out protocol

Author:

Joselyn Anita Shirley1ORCID,Teddy Dan Anna1,Jose Riya1ORCID,Shanthini Sharon23,Joseph Lallu23,Rai Ekta1ORCID,Williams Aparna1

Affiliation:

1. Department of Anaesthesia Christian Medical College & Hospital Vellore India

2. Christian Medical College & Hospital Vellore India

3. Quality Management Cell, Christian Medical College and Hospital Vellore India

Abstract

AbstractBackgroundThe time‐out protocol introduced by the Joint Commission is an important tool to prevent adverse events and improve safety in various health‐care environments. However, its implementation and utilization involve human, social, behavioral as well as system issues.AimsThe SMART aim of the current project was to increase the utilization of the time‐out protocol to more than 80% from baseline of 13%, over 6‐month period in all the magnetic resonance imaging (MRI) procedures performed at a tertiary care, teaching institute in South India.MethodsThe Plan, Do, Study, Act (PDSA) cycle and root cause analysis strategies were utilized in this quality improvement initiative. The time‐out protocol was modified for MRI environment and put into practice to improve safety. Six months after the initiation of this safety protocol, our audit showed only a 13% compliance to the time‐out protocol. A multimodal strategy was utilized by involving all the stakeholders, educational interventions, and placing reminders for following the time‐out protocol, to affect change and achieve improvement in safety.ResultsThe compliance to time‐out protocol increased from 13% to 86% and the run chart showed that a special cause variation indicated by six points above the centerline at 86%. When analyzing individual components of the time‐out, the greatest improvement was noted in the ferromagnetic check of the personnel involved, namely, the Anesthesiologist, radiographer, and anesthesia technician. There were no delays in the list because of adherence to the time‐out protocol.ConclusionTime‐out protocol in an MRI suite provides a final check to the anesthesia team before the anesthetized patient is wheeled into MR gantry. Using quality improvement methodology, we increased the compliance of time‐out protocol in the magnetic resonance imaging environment. Our study is an example how other institutions in India and elsewhere can adapt similar improvement strategies to enhance patient safety.

Publisher

Wiley

Subject

Anesthesiology and Pain Medicine,Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3