Clinical implications of imprecise sampling time for 10‐ and 30‐min thyrotropin‐releasing hormone stimulation tests in horses

Author:

Vorster Dante M.1,Wang Wenqing2,Kemp Kate L.2,Bamford Nicholas J.3ORCID,Bertin François‐René2ORCID

Affiliation:

1. Faculty of Veterinary Medicine Utrecht University Utrecht The Netherlands

2. School of Veterinary Science The University of Queensland Gatton Queensland Australia

3. Melbourne Veterinary School The University of Melbourne Parkville Victoria Australia

Abstract

AbstractBackgroundThe thyrotropin‐releasing hormone (TRH) stimulation test is used to diagnose pituitary pars intermedia dysfunction (PPID) using 10‐ or 30‐min protocols. Imprecise sampling time for the 10‐min protocol can lead to misdiagnoses.ObjectivesTo determine the effect of imprecise sampling time for the 30‐min protocol of the TRH stimulation test.Study designIn vivo experiment.MethodsPlasma immunoreactive adrenocorticotropin (ACTH) concentrations were measured 9, 10, 11, 29, 30 and 31 min after intravenous administration of 1 mg of TRH in 15 control and 12 PPID horses. Differences in ACTH concentrations between sampling times, variability in ACTH concentrations between protocols, and diagnostic classification of PPID were assessed using Friedman's test, Bland–Altman plots, and Fisher's exact test, respectively, with 95% confidence intervals reported and significance set at p < 0.05.ResultsImprecise sampling time resulted in variable ACTH concentrations, but significant differences in absolute ACTH concentrations were not detected for imprecise sampling within each protocol or between protocols. Imprecise sampling changed PPID diagnostic classification for 3/27 (11 [4–28] %) horses for both protocols. Using the 30‐min protocol as a reference, 1/12 (8 [1–35] %) horses returned a negative test result and 5/12 (42 [19–68] %) horses returned equivocal test results that would be considered positive in practice due to the presence of supportive clinical signs.Main limitationsLimited sample size and inter‐horse variability reduced the ability to detect small but potentially relevant differences.ConclusionsOverall, the impact of imprecise sampling was not significantly different between the 10‐ and 30‐min TRH stimulation test protocols. However, diagnostic classification for PPID would have varied between the 10‐ and 30‐min protocols in this population, if clinical signs had been ignored. Precise timing during TRH stimulation tests and contextual interpretation of ACTH concentrations remain fundamental for the diagnosis of PPID.

Funder

Australian Companion Animal Health Foundation

Publisher

Wiley

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3