In vitro evaluation of the impact of intraoral scanner, scanning aids, and the scanned arch on the scan accuracy of edentulous arches

Author:

Jamjoom Faris Z.12ORCID,Aldghim Adhwaa23,Aldibasi Omar45,Yilmaz Burak678ORCID

Affiliation:

1. Restorative and Prosthetic Dental Science Department College of Dentistry King Saud Bin Abdulaziz University for Health Sciences Riyadh Saudi Arabia

2. King Abdullah International Medical Research Center (KAIMRC) Riyadh Saudi Arabia

3. College of Dentistry King Saud Bin Abdulaziz University for Health Sciences Riyadh Saudi Arabia

4. Department of Biostatistics and Bioinformatics King Abdullah International Medical Research Center (KAIMRC) Riyadh Saudi Arabia

5. King Saud Bin Abdulaziz University for Health Sciences Riyadh Saudi Arabia

6. Department of Reconstructive Dentistry and Gerodontology School of Dental Medicine University of Bern Bern Switzerland

7. Department of Restorative, Preventive and Pediatric Dentistry School of Dental Medicine University of Bern Bern Switzerland

8. Division of Restorative and Prosthetic Dentistry The Ohio State University Columbus Ohio USA

Abstract

AbstractPurposeTo assess the accuracy of complete maxillary and mandibular edentulous arch scans obtained using two different intraoral scanners (IOSs), with and without scanning aids, and to compare these results to those obtained using conventional impression methods.Materials and MethodsTwo IOSs were used (TRIOS 4 [TRI] and Emerald S [EMR]) to scan maxillary and mandibular typodonts. The typodonts were scanned without scanning aids [TRI_WSA and EMR_WSA groups] (n = 10). The typodonts were then scanned under four scanning aid conditions (n = 10): composite markers [TRI_MRK and EMR_MRK groups], scanning spray [TRI_SPR and EMR_SPR groups], pressure indicating paste [TRI_PIP and EMR_PIP groups], and liquid‐type scanning aid [TRI_LQD and EMR_LQD groups]. Conventional impressions of both arches were also made using irreversible hydrocolloids in stock trays [IHC] and using polyvinyl siloxane (PVS) impression material in custom trays (n = 10) which were digitized using a laboratory scanner. Using a metrology software program, all scans were compared to a reference scan in order to assess trueness and to each other to assess precision. Trueness and precision were expressed as the root mean square (RMS) of the absolute deviation values and the statistical analysis was modeled on a logarithmic scale using fixed‐effects models to meet model assumptions (α = 0.05).ResultsThe main effect of arch (p = 0.004), scanner (p < 0.001), scanning aid (p = 0.041), and the interaction between scanner and scanning aid (p = 0.027) had a significant effect on mean RMS values of trueness. The arch (p = 0.015) and scanner (p < 0.001) had a significant effect on the mean RMS values of precision. The maxillary arch had better accuracy compared to the mandible. The TRIOS 4 scanner had better accuracy than both the Emerald S scanner and conventional impressions. The Emerald S had better precision than conventional impressions. The scanning spray and liquid‐type scanning aids produced the best trueness with the TRIOS 4 scanner, while the liquid‐type scanning aid and composite markers produced the best trueness for the Emerald S scanner.ConclusionThe scanned arch and the type of scanner had a significant effect on the accuracy of digital scans of completely edentulous arches. The scanning aid had a significant effect on the trueness of digital scans of completely edentulous arches which varied depending on the scanner used.

Funder

King Abdullah International Medical Research Center

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3