Affiliation:
1. Department of Substitutive Dental Sciences College of Dentistry Imam Abdulrahman Bin Faisal University Dammam Saudi Arabia
2. College of Dentistry Imam Abdulrahman Bin Faisal University Dammam Saudi Arabia
3. Department of Preventive Dental Sciences College of Dentistry Imam Abdulrahman Bin Faisal University Dammam Saudi Arabia
4. Department of Dental Education College of Dentistry Imam Abdulrahman Bin Faisal University Dammam Saudi Arabia
5. Department of Restorative Dental Sciences College of Dentistry Imam Abdulrahman Bin Faisal University Dammam Saudi Arabia
6. Department of Removable Prosthodontics Faculty of Dental Medicine Al‐Azhar University Assiut Egypt
7. Clinic of Masticatory Disorders and Dental Biomaterials, Center of Dental Medicine University of Zurich Zurich Switzerland
Abstract
AbstractPurposeTo evaluate the effect of different printing orientations and post‐polymerization time with thermal cycling on the translucency of 3D‐printed denture base resins.MethodsHeat‐polymerized (HP) acrylic resin specimens were fabricated and 3D‐printed denture base materials (NextDent, ASIGA, FormLabs) were printed with different printing orientations (0, 45, 90 degrees) and subjected to different post‐polymerization times (15‐, 30‐, 60‐, and 90‐min). All specimens were polished and immersed in distilled water for 1 day at 37°C. CIEDE2000 was used to measure the translucency parameters (TP00) before and after thermal cycling (5000 cycles) recording the color parameters (L*, a*, b*) against a black and white background using a spectrophotometer. k‐factors ANOVA followed by post hoc Tukey's test (α = .05) was performed for statistical analysis.ResultsThe k‐factors ANOVA test showed a significant effect of resin material, post‐polymerization time, and printing orientation on translucency (p < 0.001). In comparison to HP, all 3D‐printed resins showed lower translucency with all post‐polymerization times and printing orientation (p < 0.001) except FormLabs resin (p > 0.05). For all 3D‐printed resins, the translucency increased, with increasing the post‐polymerization time (p < 0.001) and 60‐ and 90‐min showed the highest translucency. For printing orientation, 90 and 45 degrees significantly showed high translucency in comparison to 0 degrees (p < 0.001). FormLabs showed significantly higher translucency when compared with NextDent and ASIGA per respective printing orientation and post‐polymerization time. The translucency significantly decreased after thermal cycling for all tested resins (p < 0.001).ConclusionThe findings of this study demonstrated that the translucency of 3D‐printed resins is influenced by the printing orientation, post‐polymerization time, and resin type. As a result, choosing a resin type, and printing orientation, with a longer post‐polymerization time should be considered since it may improve the esthetic appearance of the 3D‐printed resins.
Reference52 articles.
1. Procedures in complete denture prosthesis;Sussman BA;J Prosthet Dent.,1960
2. Aesthetic in complete denture‐a review;Rahman MU;J Advanc Med Dent Sci Res.,2020
3. Enhancing esthetics in a complete denture patient: optimizing results with different impression techniques;Bansod AV;Cureus.,2022
4. Optical properties and surface roughness of prepolymerized poly (methyl methacrylate) denture base materials;Alp G;J Prosthet Dent.,2019
5. Color stability of long‐term soft denture liners;Shotwell JL;J Prosthet Dent.,1992
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献