The utility of balloon‐based and standard impedance technology to diagnose esophageal mucosal diseases in children

Author:

Rosen Rachel1ORCID,Du Maritha1,Akkara Anna1,Catacora Andrea1,Wen Anna1,Liu Enju2,Nurko Samuel1ORCID

Affiliation:

1. Division of Gastroenterology, Hepatology and Nutrition, Aerodigestive Center Boston Children's Hospital Boston Massachusetts USA

2. Institutional Centers for Clinical and Translational Research Boston Children's Hospital Boston Massachusetts USA

Abstract

AbstractBackgroundStandard impedance catheters and balloon‐based mucosal impedance catheters (BBMI) have been used to assess mucosal integrity and diagnose mucosal diseases. The goal of this study was to determine the age‐related technical issues associated with mucosal balloon inflation, validate the BBMI measurement against a standard impedance probe, and compare software‐generated diagnoses to histologic diagnoses.MethodsWe prospectively recruited patients undergoing endoscopy, during which patients underwent standard mucosal impedance catheters and BBMI measurements. Measurements were compared to each other, to the histologic diagnoses, and to the number of eosinophils per high power field. We then compared the patients' diagnosis to that assigned by the BBMI software.Key ResultsSixty‐two patients (mean age: 62 ± 62 months) were recruited, including non‐GERD (N = 40), GERD (N = 15), and EoE (N = 7) patients. There were significant differences between the impedance values measured by the two technologies at each esophageal height (p < 0.003). There were significant correlations between the mean impedance values taken by the two catheters in the distal (r2 = 0.272, p = 0.04), mid (r2 = 0.371, p < 0.001), and proximal (r2 = 0.259, p = 0.05) esophagus. There were significant differences in BBMI impedance values across diagnoses in the mid and proximal esophagus (p = 0.024 and 0.025, respectively). While not statistically significant (p = 0.061–0.073), the standard catheter showed similar trends by diagnosis. Using the BBMI diagnostic prediction software, 33%–72% of patients were misclassified.Conclusion and InferencesWhile there was significant variability in impedance values between technologies within patients, regional measurements were consistent across catheters. Automated analyses lacked the sensitivity to diagnose inflammatory disorders.

Funder

National Institutes of Health

Publisher

Wiley

Subject

Gastroenterology,Endocrine and Autonomic Systems,Physiology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3