Clinical outcome of lesion size index‐guided high‐power radiofrequency catheter ablation for pulmonary vein isolation in patients with atrial fibrillation: 2‐year follow‐up

Author:

Cai Chi1,Wang Jing1ORCID,Niu Hong‐Xia1ORCID,Chu Jian‐Min1,Hua Wei1ORCID,Zhang Shu1,Yao Yan1ORCID

Affiliation:

1. Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases Chinese Academy of Medical Sciences and Peking Union Medical College Beijing China

Abstract

AbstractIntroductionThe long‐term efficacy of high‐power (50 W) ablation guided by lesion size index (LSI‐guided HP) for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) remains undetermined. Our study sought to assess the clinical efficacy of LSI‐guided HP ablation for PVI in patients with AF and explore the potential predictors associated with clinical outcomes.MethodsWe consecutively included 186 patients with AF who underwent LSI‐guided HP (50 W) ablation at Fuwai Hospital from June 2019 to October 2021. The target LSI values of 4.5–5.5 and 4.0–4.5 at the anterior and posterior walls, respectively, were used in our study. The baseline clinical characteristics, procedural and ablation data, and clinical outcomes were evaluated. The independent potential predictors associated with AF recurrence were further evaluated.ResultsThe incidence rate of first‐pass PVI was 83.9% (156/186). A total of 11 883 lesions were analyzed, and compared with posterior walls of pulmonary veins, anterior walls had significantly lower mean contact force (8.2 ± 3.0 vs. 8.3 ± 2.3 g, p = .015), longer mean radiofrequency duration (16.9 ± 7.2 vs. 12.9 ± 4.5 s, p < .001) and higher mean LSI (4.8 ± 0.2 vs. 4.4 ± 0.2, p < .001). The overall incidence of periprocedural complications was 3.7%, and steam pops without pericardial effusion occurred in three patients (1.6%). During a mean follow‐up of 24.0 ± 8.4 months, the overall AF recurrence‐free survival was 87.1% after a single procedure. Patients with paroxysmal AF had a higher incidence of freedom from AF recurrence than those with persistent AF (91.2% vs. 80.8%, log‐rank p = .034). Higher LSI (HR 0.50, p < .001) and paroxysmal AF (HR 0.39, p = .029) were significantly associated with decreased AF recurrence. By receiver operating characteristic analysis, the LSI of 4.7 and 4.3 for the anterior and posterior walls of the PVs had the highest predictive value for AF recurrence, respectively.ConclusionLSI‐guided HP (50 W) ablation for PVI was an efficient and safe strategy and led to favorable single‐procedure 2‐year AF recurrence‐free survival in patients with AF. Higher LSI and paroxysmal AF were independent predictors of decreased 2‐year AF recurrence. The LSI of 4.7 for the anterior wall and 4.3 for the posterior wall of the PVs were the best cutoff values for predicting AF recurrence after LSI‐guided HP ablation.

Publisher

Wiley

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3