Point‐of‐care β‐hydroxybutyrate measurement predicts adequate glucose metabolism suppression in cardiac FDG‐PET/CT

Author:

Hartikainen Suvi12ORCID,Tompuri Tuomo3,Laitinen Tiina1,Laitinen Tomi12

Affiliation:

1. Department of Clinical Physiology and Nuclear Medicine Kuopio University Hospital Kuopio Finland

2. Institute of Clinical Medicine University of Eastern Finland Kuopio Finland

3. Department of Clinical Physiology North Karelia Central Hospital Joensuu Finland

Abstract

AbstractAimsThe aims of our study were to evaluate whether point‐of‐care β‐hydroxybutyrate (BHB) measurement can be used to identify patients with adequate cardiac glucose metabolism suppression for cardiac [18F]‐fluoro‐2‐deoxy‐d‐glucose‐positron emission tomography with computerized tomography (FDG‐PET/CT) and to develop a pretest probability calculator of myocardial suppression using other metabolic factors attainable before imaging.Methods and ResultsWe recruited 193 patients with any clinical indication for whole body [18F]‐FDG‐PET/CT. BHB level was measured with a point‐of‐care device. Maximal myocardial standardized uptake value using lean body mass (SULmax) was measured from eight circular regions of interest with 1 cm circumference and background from left ventricular blood pool. Correlations SULmax and point‐of‐care measured BHB were analysed. The ability of BHB test to predict adequate suppression was evaluated with receiver operating characteristic analysis. Liver and spleen attenuation in computed tomography were measured to assess the presence of fatty liver. BHB level correlated with myocardial uptake and, using a cut‐off value of 0.35 mmol/L to predict adequate myocardial suppression, we reached specificity of 90% and sensitivity of 56%. Other variables to predict adequate suppression were diabetes, obesity, ketogenic diet and fatty liver. Using information attainable before imaging, we created a pretest probability calculator of inadequate myocardial glucose metabolism suppression. The area under the curve for BHB test alone was 0.802 and was 0.857 for the pretest calculator (p = 0.319).ConclusionsBHB level measured with a point‐of‐care device is useful in predicting adequate myocardial glucose metabolism suppression. More detailed assessment of other factors potentially contributing to cardiac metabolism is needed.

Funder

Kuopion Yliopistollinen Sairaala

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3