Artificial intelligence based left ventricular ejection fraction and global longitudinal strain in cardiac amyloidosis

Author:

Cotella Juan I.1ORCID,Slivnick Jeremy A.1,Sanderson Emily2,Singulane Cristiane1,O'Driscoll Jamie234,Asch Federico M.5,Addetia Karima1ORCID,Woodward Gary2,Lang Roberto M.1

Affiliation:

1. University of Chicago Medical Center Chicago Illinois USA

2. Ultromics Ltd, 4630 Kingsgate, Cascade Way, Oxford Business Park South, Oxford, OX4 2SU Oxford UK

3. Canterbury Christ Church University School of Psychology, Politics and Sociology Canterbury UK

4. Department of Cardiology St George's University Hospitals NHS Foundation Trust Tooting London UK

5. Cardiovascular Core Labs MedStar Health Research Institute Washington DC Washington USA

Abstract

AbstractBackgroundAssessment of left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS) plays a key role in the diagnosis of cardiac amyloidosis (CA). However, manual measurements are time consuming and prone to variability. We aimed to assess whether fully automated artificial intelligence (AI) calculation of LVEF and GLS provide similar estimates and can identify abnormalities in agreement with conventional manual methods, in patients with pre‐clinical and clinical CA.MethodsWe identified 51 patients (age 80 ± 10 years, 53% male) with confirmed CA according to guidelines, who underwent echocardiography before and/or at the time of CA diagnosis (median (IQR) time between observations 3.87 (1.93, 5.44 years). LVEF and GLS were quantified from the apical 2‐ and 4‐chamber views using both manual and fully automated methods (EchoGo Core 2.0, Ultromics). Inter‐technique agreement was assessed using linear regression and Bland‐Altman analyses and two‐way ANOVA. The diagnostic accuracy and time for detecting abnormalities (defined as LVEF ≤ 50% and GLS ≥ −15.1%, respectively) using AI was assessed by comparisons to manual measurements as a reference.ResultsThere were no significant differences in manual and automated LVEF and GLS values in either pre‐CA (p = .791 and p = .105, respectively) or at diagnosis (p = .463 and p = .722). The two methods showed strong correlation on both the pre‐CA (r = .78 and r = .83) and CA echoes (r = .74 and r = .80) for LVEF and GLS, respectively. The sensitivity and specificity of AI‐derived indices for detecting abnormal LVEF were 83% and 86%, respectively, in the pre‐CA echo and 70% and 79% at CA diagnosis. The sensitivity and specificity of AI‐derived indices for detecting abnormal GLS was 82% and 86% in the pre‐CA echo and 100% and 67% at the time of CA diagnosis. There was no significant difference in the relationship between LVEF (p = .99) and GLS (p = .19) and time to abnormality between the two methods.ConclusionFully automated AI‐calculated LVEF and GLS are comparable to manual measurements in patients pre‐CA and at the time of CA diagnosis. The widespread implementation of automated LVEF and GLS may allow for more rapid assessment in different disease states with comparable accuracy and reproducibility to manual methods.

Publisher

Wiley

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3