Association of leadless pacing with ventricular and valvular function

Author:

Arps Kelly1ORCID,Li Bicong1,Allen John Carson1,Alenezi Fawaz1,Frazier‐Mills Camille1,Al‐Khatib Sana M.1,Jackson Kevin P.1ORCID,Jackson Larry R.1ORCID,Thomas Kevin L.1,Piccini Jonathan P.1ORCID

Affiliation:

1. Division of Cardiovascular Disease, Section of Cardiac Electrophysiology Duke University Medical Center Durham North Carolina USA

Abstract

AbstractBackgroundTraditional transvenous pacemakers are associated with worsening tricuspid valve function due to lead‐related leaflet impingement, as well as ventricular dysfunction related to electromechanical dyssynchrony from chronic right ventricular (RV) pacing. The association of leadless pacing with ventricular and valvular function has not been well established. We aimed to assess the association of leadless pacemaker placement with changes in valvular regurgitation and ventricular function.Methods and ResultsEchocardiographic features before and after leadless pacemaker implant were analyzed in consecutive patients who received a leadless pacemaker with pre‐ and postprocedure echocardiography at Duke University Hospital between November 2014 and November 2019. Valvular regurgitation was graded ordinally from 0 (none) to 3 (severe). Among 54 patients, the mean age was mean age was 70.1 ± 14.3 years, 24 (44%) were women, and the most frequent primary pacing indication was complete heart block in 24 (44%). The median RV pacing burden was 45.4 (interquartile range [IQR] 3.5–97.0). On echocardiogram performed 8.9 months (IQR 4.5–14.5) after implant, there was no change in the average severity of tricuspid regurgitation (mean change 0.07 ± 1.15, p = .64) from pre‐procedure echocardiogram. We observed a decrease in the average left ventricular ejection fraction (LVEF) (52.3 ± 9.3 to 47.9 ± 12.1, p = .0019) and tricuspid annular plane systolic excursion (TAPSE) (1.8 ± 0.6 to 1.6 ± 0.4, p = .0437). Thirteen patients (24%) had absolute drop in LVEF of ≥10%.ConclusionWe did not observe short term worsening valvular function in patients with leadless pacemakers. However, consistent with the pathophysiologic impact of RV pacing, leadless pacing was associated with a reduction in biventricular function.

Publisher

Wiley

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3