Unipolar and bipolar electrograms to predict successful ablation site of premature ventricular contractions originating from the free wall of the tricuspid annulus

Author:

Liu Qi‐Fang1ORCID,Tian Ye1,Tian Long‐Hai1,Jing Huang1

Affiliation:

1. Department of Cardiology Guizhou Provincial People's Hospital Guiyang 550002 Guizhou China

Abstract

AbstractIntroductionThis study aimed to identify the characteristics of unipolar and bipolar electrogram (UniEGM and BiEGM) in guiding successful ablation of premature ventricular contractions (PVCs) originating from the free wall of the ventricular aspect of the tricuspid annulus (TA). We hypothesized that the negative concordance pattern (NCP) on the onset of UniEGM and BiEGM, together with the least value of the difference between the earliest BiEGM and UniEGM dV/dTmax, might improve the accuracy of conventional mapping.Methods and ResultsThirty consecutive patients who underwent successful catheter ablation from February 2018 to July 2021 were retrospectively analyzed. The BiEGM and UniEGM for successful ablation sites were compared with those for non‐successful ablation sites. Among the 30 patients, 30 successful and 26 nonsuccessful ablation sites were compared. The earliest activation time of the BiEGM (BiEGMoneset‐QRS) was 25 ± 6 ms for the successful ablation sites and 21 ± 6 ms for the nonsuccessful ablation sites (p = .47). The value of the difference in the earliest BiEGM and UniEGM dV/dTmax differed between successful and nonsuccessful ablation sites (6.4 ± 3.6 ms vs. 10.4 ± 6.8 ms). NCP was observed at 90.0% and 42.3% of the successful and nonsuccessful ablation sites, respectively. Alignment of NCP and BiEGMonset‐UniEGM ≤6 ms was applied as the mapping criterion for successful PVC suppression (73.1% sensitivity and 87.7% specificity). The area under the receiver‐operating characteristic curve for this cutoff was 0.85.ConclusionMapping based on an NCP at the onset of the BiEGM and UniEGM and the least difference value of the earliest BiEGM and UniEGM dV/dTmax had an excellent predictive value for successful ablation. These strategies may reduce the number of radiofrequency catheter ablation (RFCA) applications for free‐wall tricuspid annular PVCs.

Publisher

Wiley

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3