Accuracy, precision, and interobserver and intraobserver agreements related to pressure‐measurement devices

Author:

Chen Carolyn L.1,Wallace Mandy L.1ORCID,Reed Rachel A.2,Grimes Janet A.1ORCID

Affiliation:

1. Department of Small Animal Medicine and Surgery, College of Veterinary Medicine University of Georgia Athens Georgia USA

2. Department of Large Animal Medicine, College of Veterinary Medicine University of Georgia Athens Georgia USA

Abstract

AbstractObjectiveTo evaluate the accuracy, precision, and observer agreement of three pressure measurement devices.Study DesignIn vitro model study.Sample PopulationWater manometer with built‐in gauge (WMg), arterial pressure transducer (APT), and Compass CT (CCT).MethodsThe model was set to five predetermined pressures (4, 8, 13, 17, and 24 cm H2O) using a water manometer with a ruler (WMr) as the gold standard. Each device was tested at each pressure in a randomized order by three investigators. Bland–Altman plots were used to assess agreement between devices. Intraclass correlation coefficients (ICC) were calculated for interobserver and intraobserver agreements.ResultsThe mean differences (cm H2O) ± SEM in comparison with the set pressure were −0.020 ± 0.010 (WMg), −0.390 ± 0.077 (APT), and −1.267 ± 0.213 (CCT). Pressures measured by WMg did not differ from those measured by WMr. Pressures measured by all devices did not differ from each other (p > .062 for all comparisons). Interobserver agreement was excellent (1.000), and intraobserver agreement was excellent (0.985, 0.990, 0.998 for each observer).ConclusionCompared to the WMr, the WMg was the most accurate and precise, followed by the APT; the CCT was the least accurate and precise. Interobserver and intraobserver agreements for all three devices were excellent.Clinical SignificanceThe largest mean difference of all devices was within 1.3 cm H2O of the set pressure, indicating possible clinical utility of any of the devices. However, WMr or WMg should be considered first due to their high precision and accuracy.

Publisher

Wiley

Subject

General Veterinary

Reference17 articles.

1. Endovascular evaluation and treatment of intrahepatic portosystemic shunts in dogs: 100 cases (2001–2011)

2. Intrahepatic and extrahepatic portal venous anomalies in dogs: 52 cases (1982–1992);Bostwick DR;J Am Vet Med Assoc,1995

同舟云学术