AbstractPurposeRefractions based on the optimisation of single‐value wavefront‐derived metrics may help determine appropriate corrections for individuals with Down syndrome where clinical techniques fall short. This study compared dioptric differences between refractions obtained using standard clinical techniques and two metric‐optimised methods: visual Strehl ratio (VSX) and pupil fraction tessellated (PFSt), and investigated characteristics that may contribute to the differences between refraction types.MethodsThirty adults with Down syndrome (age = 29 ± 10 years) participated. Three refractive corrections (VSX, PFSt and clinical) were determined and converted to vector notation (M, J0, J45) to calculate the dioptric difference between pairings of each type using a mixed model repeated measures approach. Linear correlations and multivariable regression were performed to examine the relationship between dioptric differences and the following participant characteristics: higher order root mean square (RMS) for a 4 mm pupil diameter, spherical equivalent refractive error and Vineland Adaptive Behavior Scales (a measure of developmental ability).ResultsThe least squares mean estimates (standard error) of the dioptric differences for each pairing were as follows: VSX versus PFSt = 0.51 D (0.11); VSX versus clinical = 1.19 D (0.11) and PFSt versus clinical = 1.04 D (0.11). There was a statistically significant difference in the dioptric differences between the clinical refraction and each of the metric‐optimised refractions (p < 0.001). Increased dioptric differences in refraction were correlated with increased higher order RMS (R = 0.64,p < 0.001 [VSX vs. clinical] andR = 0.47,p < 0.001 [PFSt vs. clinical]) as well as increased myopic spherical equivalent refractive error (R = 0.37,p = 0.004 [VSX vs. clinical] andR = 0.51,p < 0.001 [PFSt vs. clinical]).ConclusionsThe observed differences in refraction demonstrate that a significant portion of the refractive uncertainty is related to increased higher order aberrations and myopic refractive error. Methodology surrounding clinical techniques and metric‐optimisation based on wavefront aberrometry may explain the difference in refractive endpoints.

Funder

National Eye Institute

Publisher

Wiley

Subject

Sensory Systems,Optometry,Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3