AbstractPurposeThis study was performed with the aim of finding a more convenient and less time‐consuming method to diagnose retinal breaks in posterior vitreous detachment (PVD) patients.MethodsA prospective double‐blind observational case study was performed with patients who were admitted to the Eye Emergency Department Sahlgrenska University Hospital with PVD symptoms and approved to participate in the study (n = 128). Standard slit lamp examination was compared with images from a Zeiss Clarus 700 ultra‐wide‐field camera (UWFC). Patients were examined and photographed by an independent operator. Data and image review was performed by three independent reviewers with varying experience. Retinal break detection with the two different methods (detailed eye examination by well‐trained ophthalmologist and UWFC evaluations) was analysed statistically.ResultsAfter excluding diagnoses other than PVD as well as unclear images due to cataracts, vitreous bleeding, etc., a total of 103 eyes with PVD were evaluated. A total of 38 ruptures in 25 patients were detected by routine examination and were subjected to laser treatment. UWFC images were reviewed by three ophthalmology consultants and compared with routine examinations. Sensitivity values in detecting retinal ruptures in UWFC images of the three reviewers were 0.89, 0.87 and 0.79, and specificity values were 0.88, 0.86 and 0.93 (kappa values: 0.742, 0.689 and 0.728) respectively.ConclusionAlthough there have been rapid developments in imaging with UWFC in recent years and it is a very promising method for the future, routine clinical examination is still the only valid method for the detection of retinal tears today.

Publisher

Wiley

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3