Determination of optimal positive end‐expiratory pressure using electrical impedance tomography in infants under general anesthesia: Comparison between supine and prone positions

Author:

Lee Ji‐Hyun1,Kang Pyoyoon1,Park Jung‐Bin1,Ji Sang‐Hwan1,Jang Young‐Eun1,Kim Eun‐Hee1ORCID,Kim Jin‐Tae1,Kim Hee‐Soo1ORCID

Affiliation:

1. Department of Anesthesiology and Pain Medicine, Seoul National University Hospital Seoul National University College of Medicine Seoul South Korea

Abstract

AbstractAimsThis study determined the optimal positive end‐expiratory pressure levels in infants in supine and prone positions under general anesthesia using electrical impedance tomography (EIT).MethodsThis prospective observational single‐centre study included infants scheduled for surgery in the prone position. An electrical impedance tomography sensor was applied after inducing general anesthesia. The optimal positive end‐expiratory pressure in the supine position was determined in a decremental trial based on EIT and compliance. Subsequently, the patient's position was changed to prone. Electrical impedance tomography parameters, including global inhomogeneity index, regional ventilation delay, opening pressure, the centre of ventilation, and pendelluft volume, were continuously obtained up to 1 h after prone positioning. The optimal positive end‐expiratory pressure in the prone position was similarly determined.ResultsData from 30 infants were analyzed. The mean value of electrical impedance tomography‐based optimal positive end‐expiratory pressure in the prone position was significantly higher than that in the supine position [10.9 (1.6) cmH2O and 6.1 (0.9) cmH2O, respectively (p < .001)]. Significant differences were observed between electrical impedance tomography‐ and compliance‐based optimal positive end‐expiratory pressure. Peak and mean airway, plateau, and driving pressures increased 1 h after prone positioning compared with those in the supine position. In addition, the centre of ventilation for balance in ventilation between the ventral and dorsal regions improved.ConclusionThe prone position required higher positive end‐expiratory pressure than the supine position in mechanically ventilated infants under general anesthesia. EIT is a promising tool to find the optimal positive end‐expiratory pressure, which needs to be individualized.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3