Accuracy of the Apple watch for detection of AF: A multicenter experience

Author:

Wasserlauf Jeremiah1ORCID,Vogel Kelly2,Whisler Cailin3,Benjamin Emelia4ORCID,Helm Robert4,Steinhaus Daniel A.5,Yousuf Omair6,Passman Rod S.2ORCID

Affiliation:

1. North Shore University Health System Evanston Illinois USA

2. Northwestern Medicine Chicago Illinois USA

3. Johns Hopkins University School of Medicine Baltimore Maryland USA

4. Boston University School of Medicine Boston Massachusetts USA

5. Saint Luke's Cardiovascular Consultants Kansas City Missouri USA

6. Carient Heart & Vascular Manassas Virginia USA

Abstract

AbstractIntroductionThe Apple watch (AW) irregular rhythm notification (IRN) feature uses photoplethysmography to identify prolonged episodes of irregular rhythm suggestive of atrial fibrillation (AF). IRN is FDA cleared for those with no previous history of AF, however, these devices are increasingly being used for AF management. The objective of the present study was to determine the accuracy of the IRN in subjects with a previous diagnosis of nonpermanent AF.MethodsSubjects with a history of nonpermanent AF and either an insertable cardiac monitor (ICM) or cardiac implanted electronic device (CIED) with <5% ventricular pacing were fitted with an AW Series 5 for 6 months. AF episodes were compared between the ICM/CIED and IRN. The primary endpoints were sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the IRN by subject for AF ≥1 h. Secondary endpoints were sensitivity and PPV by AF episode ≥1 h. Analysis was limited to a maximum of 10 ICM/CIED episodes per subject and included only those AF episodes occurring during active AW use confirmed by activity data.ResultsThirty participants were enrolled. Mean age was 65.4 ± 12.2 years and 40% were female. There were 10 ICMs and 20 CIEDs. Eleven subjects had AF on ICM/CIED while the AW was worn, of whom 8 were detected by IRN. There were no false positive IRN detections by subject (“by subject” 72% sensitivity, 100% specificity, 100% PPV, and 90% NPV). Five subjects had AF only when the AW was not worn. There were a total of 70 AF episodes on ICM/CIED, 35 of which occurred while the AW was being worn. Of these, 21 were detected by IRN with 1 false positive (“by episode” sensitivity = 60.0%, PPV = 95.5%).ConclusionIn a population with known AF, the AW IRN had a low rate of false positive detections and high specificity. Sensitivity for detection by subject and by AF episode was lower. The current IRN algorithm appears accurate for AF screening as currently cleared, but increased sensitivity and wear times would be necessary for disease management.

Publisher

Wiley

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3